AJR ARRS Membership
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Barnes, G.
Right arrow Articles by Witten, D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Barnes, G.
Right arrow Articles by Witten, D.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
American Journal of Roentgenology, Vol 129, Issue 3, 497-501
Copyright © 1977 by American Roentgen Ray Society


Articles

Scanning multiple slit assembly: a practical and efficient device to reduce scatter

GT Barnes, IA Brezovich, and DM Witten

A scanning multiple slit assembly consisting of an array of long narrow beam-defining slits coupled with scatter-eliminating slots beneath the patient is a feasible, practical, and efficient method of reducing scatter and increasing contrast and image quality in diagnostic radiology. Measurements of the ratio of scattered-to-primary radiation transmitted by a scanning multiple slit assembly and a conventional high ratio grid under similar conditions showed the relative intensity of scatter transmitted by the slit assembly to be only one-third that of the grid. A noticeable improvement in contrast was obtained using the slit assembly, without increase in patient exposure. The design, construction, and clinical implications of such a scatter-eliminating technique are discussed.
Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
RadiologyHome page
H. P. McAdams, E. Samei, J. Dobbins III, G. D. Tourassi, and C. E. Ravin
Recent Advances in Chest Radiography
Radiology, December 1, 2006; 241(3): 663 - 683.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
E. Samei, J. Y. Lo, T. T. Yoshizumi, J. L. Jesneck, J. T. Dobbins II, C. E. Floyd Jr, H. P. McAdams, and C. E. Ravin
Comparative Scatter and Dose Performance of Slot-Scan and Full-Field Digital Chest Radiography Systems
Radiology, June 1, 2005; 235(3): 940 - 949.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1977 by the American Roentgen Ray Society.