Articles |
Chronic hemodialysis requires an adequately functioning, surgically created vascular access. Many operative techniques have been devised, and each is subject to a variety of complications that significantly shorten the life span of any shunt. Among these are stenosis, thrombosis, aneurysm, pseudoaneurysm, and infection. High resolution sonography is a promising means to evaluate most of these complications. To determine the potential capability of the technique for detecting graft complications, a retrospective review of 30 hemodialysis patients examined with high resolution sonography is presented. Sonographic findings in normal grafts and in a variety of vascular access problems are illustrated.
This article has been cited by other articles:
![]() |
D. A. Mayer, R. G. Zingale, and M. J. Tsapogas Duplex Scanning of Expanded Polytetrafluoroethylene Dialysis Shunts: Impact on Patient Management and Graft Survival Vascular and Endovascular Surgery, November 1, 1993; 27(9): 647 - 658. [Abstract] [PDF] |
||||