|
|
||||||||
Articles |
Computed tomography potentially offers the most accurate noninvasive means of estimating in vivo volumes. Contiguous 1-cm-thick CT scans were obtained through phantoms, dog kidneys in vivo, and human spleens before splenectomy. Cross-sectional areas were calculated for each individual scan and volumes then determined with each of four mathematical integration techniques. Volume estimations were compared to volumes determined by water displacement. The simplest, most practical means of calculating volumes, using the summation-of-areas technique with scans obtained at 2 cm intervals, was similar in accuracy to more complex methods. The mean percentage error of volume calculations using the sum-of-areas technique was 4.95% for five immobile phantoms, 3.86% for eight dog kidneys, 3.59% for eight human spleens in vivo at 1 cm scan spacing, and 3.65% for the same human spleens at 2 cm scan spacings. Difficulties in visual recognition and manual tracking of object boundaries seem to be more significant sources of error than patient-related factors.
This article has been cited by other articles:
![]() |
Y. Park, D. Choi, H. K. Lim, H. Rhim, Y.-s. Kim, S. H. Kim, and W. J. Lee Growth Rate of New Hepatocellular Carcinoma After Percutaneous Radiofrequency Ablation: Evaluation with Multiphase CT Am. J. Roentgenol., July 1, 2008; 191(1): 215 - 220. [Abstract] [Full Text] [PDF] |
||||
![]() |
Y.-s. Kim, H. K. Lim, H. Rhim, W. J. Lee, J. W. Joh, and C. K. Park Recurrence of Hepatocellular Carcinoma After Liver Transplantation: Patterns and Prognostic Factors Based on Clinical and Radiologic Features Am. J. Roentgenol., August 1, 2007; 189(2): 352 - 358. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. de Fost, J. M.F.G. Aerts, J. E.M. Groener, M. Maas, E. M. Akkerman, M. G. Wiersma, and C. E.M. Hollak Low frequency maintenance therapy with imiglucerase in adult type I Gaucher disease: a prospective randomized controlled trial Haematologica, February 1, 2007; 92(2): 215 - 221. [Abstract] [Full Text] [PDF] |
||||
![]() |
A.-J. Lemke, M. J. Brinkmann, T. Schott, S. M. Niehues, U. Settmacher, P. Neuhaus, and R. Felix Living Donor Right Liver Lobes: Preoperative CT Volumetric Measurement for Calculation of Intraoperative Weight and Volume Radiology, September 1, 2006; 240(3): 736 - 742. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. de Fost, C. E. M. Hollak, J. E. M. Groener, J. M. F. G. Aerts, M. Maas, L. W. Poll, M. G. Wiersma, D. Haussinger, S. Brett, N. Brill, et al. Superior effects of high-dose enzyme replacement therapy in type 1 Gaucher disease on bone marrow involvement and chitotriosidase levels: a 2-center retrospective analysis Blood, August 1, 2006; 108(3): 830 - 835. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. J. Pickhardt, V. T. Lehman, T. C. Winter, and A. J. Taylor Polyp volume versus linear size measurements at CT colonography: implications for noninvasive surveillance of unresected colorectal lesions. Am. J. Roentgenol., June 1, 2006; 186(6): 1605 - 1610. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. S. Bezerra, G. D'Ippolito, S. Faintuch, J. Szejnfeld, and M. Ahmed Determination of Splenomegaly by CT: Is There a Place for a Single Measurement? Am. J. Roentgenol., May 1, 2005; 184(5): 1510 - 1513. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. C. Thoeny, P. R. Delaere, and R. Hermans Correlation of Local Outcome after Partial Laryngectomy with Cartilage Abnormalities on CT AJNR Am. J. Neuroradiol., March 1, 2005; 26(3): 674 - 678. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. L. Spielmann, D. M. DeLong, and M. A. Kliewer Sonographic Evaluation of Spleen Size in Tall Healthy Athletes Am. J. Roentgenol., January 1, 2005; 184(1): 45 - 49. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. Rylander, M. Hogman, G. Perchiazzi, A. Magnusson, and G. Hedenstierna Functional Residual Capacity and Respiratory Mechanics as Indicators of Aeration and Collapse in Experimental Lung Injury Anesth. Analg., March 1, 2004; 98(3): 782 - 789. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. M. Yetter, K. B. Acosta, M. C. Olson, and K. Blundell Estimating Splenic Volume: Sonographic Measurements Correlated with Helical CT Determination Am. J. Roentgenol., December 1, 2003; 181(6): 1615 - 1620. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. H. Schwartz, M. Mazumdar, W. Brown, A. Smith, and D. M. Panicek Variability in Response Assessment in Solid Tumors: Effect of Number of Lesions Chosen for Measurement Clin. Cancer Res., October 1, 2003; 9(12): 4318 - 4323. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. C. Blackmore, G. J. Jurkovich, K. F. Linnau, P. Cummings, E. K. Hoffer, and F. P. Rivara Assessment of Volume of Hemorrhage and Outcome From Pelvic Fracture Arch Surg, May 1, 2003; 138(5): 504 - 509. [Abstract] [Full Text] [PDF] |
||||
![]() |
B. V. Czermak, P. Waldenberger, R. Perkmann, M. Rieger, I. E. Steingruber, A. Mallouhi, G. Fraedrich, and W. R. Jaschke Placement of Endovascular Stent-Grafts for Emergency Treatment of Acute Disease of the Descending Thoracic Aorta Am. J. Roentgenol., August 1, 2002; 179(2): 337 - 345. [Abstract] [Full Text] [PDF] |
||||
![]() |
P M Lamb, A Lund, R R Kanagasabay, A Martin, J A W Webb, and R H Reznek Spleen size: how well do linear ultrasound measurements correlate with three-dimensional CT volume assessments? Br. J. Radiol., July 1, 2002; 75(895): 573 - 577. [Abstract] [Full Text] [PDF] |
||||
![]() |
W. P. Fairfield, M. Treat, D. I. Rosenthal, W. Frontera, T. Stanley, C. Corcoran, M. Costello, K. Parlman, D. Schoenfeld, A. Klibanski, et al. Effects of testosterone and exercise on muscle leanness in eugonadal men with AIDS wasting J Appl Physiol, June 1, 2001; 90(6): 2166 - 2171. [Abstract] [Full Text] [PDF] |
||||
![]() |
B. V. Czermak, P. Waldenberger, G. Fraedrich, A. H. Dessl, K. E. Roberts, R. J. Bale, R. Perkmann, and W. R. Jaschke Treatment of Stanford Type B Aortic Dissection with Stent-Grafts: Preliminary Results Radiology, November 1, 2000; 217(2): 544 - 550. [Abstract] [Full Text] |
||||
![]() |
L. M. MALBOUISSON, C. J. BUSCH, L. PUYBASSET, Q. LU, P. CLUZEL, J.-J. ROUBY, and the CT Scan ARDS Study Gr Role of the Heart in the Loss of Aeration Characterizing Lower Lobes in Acute Respiratory Distress Syndrome Am. J. Respir. Crit. Care Med., June 1, 2000; 161(6): 2005 - 2012. [Abstract] [Full Text] |
||||
![]() |
K. D. Hopper, K. Singapuri, and A. Finkel Body CT and Oncologic Imaging Radiology, April 1, 2000; 215(1): 27 - 40. [Abstract] [Full Text] |
||||
![]() |
B. D. Cheson, S. J. Horning, B. Coiffier, M. A. Shipp, R. I. Fisher, J. M. Connors, T. A. Lister, J. Vose, A. Grillo-Lopez, A. Hagenbeek, et al. Report of an International Workshop to Standardize Response Criteria for Non-Hodgkin's Lymphomas J. Clin. Oncol., April 1, 1999; 17(4): 1244 - 1244. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. G. Sorensen, W. A. Copen, L. Østergaard, F. S. Buonanno, R. G. Gonzalez, G. Rordorf, B. R. Rosen, L. H. Schwamm, R. M. Weisskoff, and W. J. Koroshetz Hyperacute Stroke: Simultaneous Measurement of Relative Cerebral Blood Volume, Relative Cerebral Blood Flow, and Mean Tissue Transit Time Radiology, February 1, 1999; 210(2): 519 - 527. [Abstract] [Full Text] |
||||
![]() |
H. K. Lim, D. Choi, W. J. Lee, S. H. Kim, S. J. Lee, H.-J. Jang, J.-H. Lee, J. H. Lim, and I. W. Choo Hepatocellular Carcinoma Treated with Percutaneous Radio-frequency Ablation: Evaluation with Follow-up Multiphase Helical CT Radiology, November 1, 2001; 221(2): 447 - 454. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |