AJR InPractice
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Herman, P.
Right arrow Articles by Balikian, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Herman, P.
Right arrow Articles by Balikian, J.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
American Journal of Roentgenology, Vol 138, Issue 3, 485-489
Copyright © 1982 by American Roentgen Ray Society


Articles

350 kV chest radiography has no diagnostic advantage: a comparison with 140 kV technique

PG Herman, J Drummey, RG Swensson, SJ Hessel, and JP Balikian

It has been suggested that a 350 kV technique will produce better chest radiographs than lower kilovoltage techniques. This is because the 350 kV x-ray spectrum provides better penetration of the overlying bony structures and results in a clearer delineation of the mediastinum. Fifty cases, containing 92 definite and significant abnormalities, were selected from a pool of 500 patients who had both 350 and 140 kV chest radiographs on the same day. The 50 paired films were studied at separate times by five experienced radiologists. The interpretations were analyzed for accuracy, significance, and confidence level; interpretation times and the utility of the lateral radiograph were also noted. When all the definitely and potentially significant abnormal findings were considered, the 350 kV films produced fewer true-positive reports and more false-positive reports than the 140 kV films. The receiver operating characteristic (ROC) curves, constructed from the observers' confidence ratings, were shifted toward less satisfactory performance for the 350 kV readings. When only statements about nodules and masses were considered, identical ROC curves were produced by the two techniques. Despite their potential advantages, the 350 kV films showed no diagnostic superiority over the 140 kV films.
Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
RadiologyHome page
R. V. Kaczmarek, B. J. Conway, R. O. Slayton, and O. H. Suleiman
Results of a Nationwide Survey of Chest Radiography: Comparison with Results of a Previous Study
Radiology, June 1, 2000; 215(3): 891 - 896.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1982 by the American Roentgen Ray Society.