Articles |
Arterially injected carbon dioxide coupled with digital subtraction fluoroscopy consistently produced clinically useful images of arteries in 17 patients. Occasionally good parenchymal images and venograms were also obtained. The buoyancy of the gas requires that the area of interest be in a nondependent position to insure good arterial perfusion. The exceedingly low viscosity of gas should permit delivery of the CO2 via microcatheters which would lessen the risk of arterial injury. CO2 does not produce hypersensitivity reactions and, even in large volumes, should not produce the discomfort associated with iodinated contrast material.
This article has been cited by other articles:
![]() |
D O Kessel, I Robertson, J V Patel, S Simpson, and E J Taylor Angiographic strategies when iodinated contrast medium is undesirable Imaging, December 15, 2001; 13(5): 349 - 356. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. J. Spinosa, A. H. Matsumoto, J. F. Angle, K. D. Hagspiel, J. K. McGraw, and C. Ayers Renal Insufficiency: Usefulness of Gadodiamide-enhanced Renal Angiography to Supplement CO2-enhanced Renal Angiography for Diagnosis and Percutaneous Treatment Radiology, March 1, 1999; 210(3): 663 - 672. [Abstract] [Full Text] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |