AJR Track the topics, authors and articles important to you
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Fisher, M.
Right arrow Articles by Doerner, S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Fisher, M.
Right arrow Articles by Doerner, S.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
American Journal of Roentgenology, Vol 139, Issue 6, 1055-1059
Copyright © 1982 by American Roentgen Ray Society


Articles

Evaluation of a new mobile automatic exposure control device

MR Fisher, RA Mintzer, LF Rogers, PJ Lin, JB Bova, and SM Doerner

Mobile chest radiographs obtained with manual technique and with an automatic exposure control device were compared in 50 patients requiring three radiographs within a 48 hr period. Parameters evaluated were overall quality, internal consistency, film latitude, lung field (consistency and quality), cardiac contour, hilar anatomy, pulmonary vascularity, mediastinum, tracheobronchial tree, and tubes and appliances. Radiographs obtained with the automatic exposure control system demonstrated better overall quality, consistency, film latitude, and lung field consistency and quality than manual technique. There was no definite advantage of the automatic exposure control device in the visualization of the hila, pulmonary vascularity, heart, or mediastinum. Tubes and appliances were seen equally well with both techniques. The automatic exposure control device has the potential to increase the quality and consistency of mobile radiographs, particularly in those critically ill patients who are radiographed at least on a daily basis.
Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1982 by the American Roentgen Ray Society.