AJR Women's Imaging Online
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Pfister, R.
Right arrow Articles by Travers, E
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Pfister, R.
Right arrow Articles by Travers, E
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
American Journal of Roentgenology, Vol 140, Issue 1, 149-153
Copyright © 1983 by American Roentgen Ray Society


Articles

Contrast-medium-induced electrocardiographic abnormalities: comparison of bolus and infusion of methylglucamine iodamide and methylglucamine/sodium diatrizoate

RC Pfister, AM Hutter Jr, JH Newhouse, IC Yoder, and E Travers

A double-blind study comparing electrocardiographic (ECG) abnormalities induced by methyglucamine iodamide and methylglucamine/sodium diatrizoate was conducted in 189 patients. The media were each administered by both bolus and infusion. Iodamide caused fewer ECG changes both by injection and infusion. This contrast medium also resulted in fewer ECG changes in the patient groups with known prior ECG abnormalities, cardiovascular disease, arrhythmias, ischemia, or renal impairment and in those over 50 years of age. Digitalis did not increase the frequency of ECG abnormalities with either medium. With diatrizoate, the lower bolus dose produced as many major ECG changes in the presence of preexisting ECG abnormalities (arrhythmias, ischemia) or prior cardiovascular disease as the three-times-larger infusion dose more slowly administered; conversely, the opposite was found when renal insufficiency or older age existed. The conclusion is that iodamide media caused fewer ECG abnormalities and may be less hazardous.
Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
Arch NeurolHome page
J. B. Ball Jr, R. R. Lukin, T. A. Tomsick, and A. A. Chambers
Complications of Intravenous Digital Subtraction Angiography
Arch Neurol, October 1, 1985; 42(10): 969 - 972.
[Abstract] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1983 by the American Roentgen Ray Society.