AJR Join ARRS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Webb, W.
Right arrow Articles by Moore, E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Webb, W.
Right arrow Articles by Moore, E.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
American Journal of Roentgenology, Vol 143, Issue 4, 723-727
Copyright © 1984 by American Roentgen Ray Society


Articles

Evaluation of magnetic resonance sequences in imaging mediastinal tumors

WR Webb, G Gamsu, DD Stark, KL Moon Jr, and EH Moore

Ten patients having a mediastinal tumor were studied with magnetic resonance imaging (MRI) using from two to four imaging sequences. Seven had bronchial carcinoma and three had benign lesions. The sequences included the spin-echo technique with repetition time (TR) values of 0.5, 1.0, and 2.0 sec and echo time (TE) values of 28 and 56 msec, and the inversion-recovery technique. The signal-intensity ratios of the mediastinal mass and mediastinal fat, which are a measure of image contrast, were compared for the different imaging sequences. Also signal-to-noise ratios were measured relative to both mediastinal fat and mediastinal mass. With spin-echo imaging, decreasing the TR value resulted in an increase in mass/fat contrast in all patients, making the masses easier to detect, but this also resulted in decreased signal-to-noise ratios. Inversion-recovery imaging with the sequence used resulted in a greatly increased mass/fat contrast, because of a relative decrease in signal from the mass. However, in two of four patients studied with this technique, the mass was so low in intensity that it could not be distinguished from the trachea or mediastinal vessels, and in one of these four, a lung nodule was also invisible. Spin-echo imaging with both short and long TR values provides good tissue contrast and good signal-to-noise ratios.
Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1984 by the American Roentgen Ray Society.