AJR ARRS Member Benefits
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kinney, T.
Right arrow Articles by Fogarty, T.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kinney, T.
Right arrow Articles by Fogarty, T.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
American Journal of Roentgenology, Vol 144, Issue 1, 115-122
Copyright © 1985 by American Roentgen Ray Society


Articles

Shear force in angioplasty: its relation to catheter design and function

TB Kinney, M Fan, AK Chin, JC Finn, WG Hayden, and TJ Fogarty

The inability to successfully position angioplasty catheters and the occurrence of complications during angioplasty procedures can, in part, be related to the shear forces generated during catheter introduction. Shear forces are the axial contact forces that the catheter system exerts on the inner arterial surfaces during advancement. The shear forces exerted by three different catheter designs (coaxial dilator, coaxial balloon, and linear extrusion) were measured in normal and atherosclerotic arteries; in modeled stenoses of variable severity, length, and compliance; and in modeled vessel angulations. The results with modeled vessels show that the linear extrusion catheter reduces the level of shear forces, particularly in narrow, long, noncompliant stenoses and in tortuous vessels. The stenotic artery results also show that the linear extrusion catheter minimizes these forces in tight lesions. The relative differences in forces are explained by the mechanism of action for each catheter. The reported occurrences of technical difficulties, complications, and long-term patency rates are then interpreted on the basis of the relative differences in measured shear forces. The results of this study combined with preliminary clinical data indicate that linear extrusion should facilitate placement and reduce associated complications.
Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1985 by the American Roentgen Ray Society.