AJR Women's Imaging Online
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by de Geer, G
Right arrow Articles by Webb, W.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by de Geer, G
Right arrow Articles by Webb, W.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
American Journal of Roentgenology, Vol 147, Issue 1, 21-25
Copyright © 1986 by American Roentgen Ray Society


Articles

Evaluation of a chest phantom for CT nodule densitometry

G de Geer, G Gamsu, C Cann, and WR Webb

The characteristics of a chest phantom used for CT nodule densitometry were determined by use of a GE CT 9800 scanner (General Electric, Milwaukee, WI). The supplied reference rods were scanned in different positions within the lung fields of the phantom and with varied chest wall thicknesses. The liver/spleen inserts were added. The CT attenuation values of different-size rods and their mineral content were also tested. The size of the standard rod is the major determinant of its CT number, which varied from 1 to 83 H. The standard rods contained no measurable calcium or other mineral. Position-dependent variability in CT numbers was relatively small with the GE CT 9800 scanner. The simulated chest wall additions and liver/spleen inserts produced only small increases in CT density. We conclude that the GE CT 9800 scanner, as an example of one of the newer CT scanners, shows improved operating characteristics for pulmonary nodule densitometry. Nodule densitometry should be further evaluated with simplified phantoms.