Articles |
Fifteen adults underwent gated cardiac MR scans in the right anterior oblique position. End-diastolic and end-systolic images were acquired in an imaging plane parallel to the ventricular septum using spin-echo image acquisition on a 0.35-T system. Analysis of ventricular volumes and ejection fractions was performed using the area-length method. These results were correlated with ejection fractions obtained from angiocardiography. The linear regression line obtained for ejection fraction was y = 0.74x + 16 and the r value was 0.789, indicating a reasonable correlation between the two methods.
This article has been cited by other articles:
![]() |
H. Matsuoka, M. Hamada, T. Honda, T. Kobayashi, M. Suzuki, T. Ohtani, M. Takezaki, M. Abe, Y. Fujiwara, T. Sumimoto, et al. Measurement of Cardiac Chamber Volumes by Cine Magnetic Resonance Imaging Angiology, April 1, 1993; 44(4): 321 - 327. [Abstract] [PDF] |
||||