AJR Join ARRS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Stein, M.
Right arrow Articles by Julien, P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Stein, M.
Right arrow Articles by Julien, P.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
American Journal of Roentgenology, Vol 147, Issue 6, 1133-1137
Copyright © 1986 by American Roentgen Ray Society


Articles

MR imaging of pulmonary emboli: an experimental study in dogs

MG Stein, JV Crues 3rd, WG Bradley Jr, KE Kortman, TA Andrues, AD Waxman, RW Henderson, and PJ Julien

Experimental pulmonary emboli, consisting of tantalum-labeled autologous blood clots and barium-labeled 3-mm plastic spheres that did not produce an MR signal, were introduced through the femoral vein into each of five dogs. The sensitivity of MR to detect autologous clots of known size was assessed, and the size of the clot on MR was compared with its actual size. Emboli were localized by using chest radiographs made in multiple projections. Cardiac-synchronized MR imaging was performed on a 0.35-T superconducting magnet and was followed by a 99mTc macroaggregated lung scan. All 12 blood clots larger than 3 mm, and three of 20 clots less than 3 mm in transverse diameter were correctly visualized with MR. Five of the 15 clots seen on MR were larger than 150% of the actual size. There were nine false-positive emboli on MR. Two of six plastic spheres resulted in an abnormal signal on MR. MR signal from pulmonary emboli results from the thrombus itself and probably also from slow blood flow proximal to the obstruction. MR may be of value in detecting pulmonary emboli; clinical trials to evaluate its usefulness should be carried out.
Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1986 by the American Roentgen Ray Society.