AJR Join ARRS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by McGahan, J.
Right arrow Articles by Walter, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by McGahan, J.
Right arrow Articles by Walter, J.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
American Journal of Roentgenology, Vol 147, Issue 6, 1241-1246
Copyright © 1986 by American Roentgen Ray Society


Articles

Portable real-time sonographic and needle guidance systems for aspiration and drainage

JP McGahan, MW Anderson, and JP Walter

One hundred and two aspiration or drainage procedures were reviewed to determine the value of portable sonographic and real-time needle guidance systems. While the majority of thoracenteses or abdominal paracenteses were performed without the aid of real-time guidance, these systems were instrumental in the development of new procedures such as percutaneous cholecystostomy and in the drainage of small fluid collections in critical areas. Portable sonographic guidance was used in 32 cases, mostly for thoracentesis or abdominal paracentesis, but it had its greatest value in guiding drainage procedures at the bedside in critically ill patients. These portable drainage procedures included four cholecystostomies, one nephrostomy, drainage of two abdominal abscesses, and two empyema drainages. Complications included one case of an enterocutaneous fistula and one case of hemoptysis after thoracentesis. The failure rate was less than 7%. The use of portable real-time sonographic and needle-guidance systems has a direct impact on improving patient care.
Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1986 by the American Roentgen Ray Society.