AJR Women's Imaging Online
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Zamenhof, R.
Right arrow Articles by Morgan, H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Zamenhof, R.
Right arrow Articles by Morgan, H.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
American Journal of Roentgenology, Vol 149, Issue 3, 631-637
Copyright © 1987 by American Roentgen Ray Society


Articles

An improved method for estimating the entrance exposure in diagnostic radiographic examinations

RG Zamenhof, S Shahabi, and HT Morgan

There is currently a widespread consensus on the importance of monitoring patient radiation exposures during radiographic examinations. Diagnostic facilities under federal jurisdiction already legislate maximum patient exposure limits for various diagnostic radiologic examinations, while an increasing number of state legislatures have instituted such regulations. Compliance requires that institutions be capable of assessing each patient's entrance exposures. A method is proposed that would facilitate the acquisition of such patient exposure information in a relatively straightforward and accurate manner, requiring a minimum number of measurements and access to a suitable programmable calculator. A standardized set of exposure measurements obtained on an accurately calibrated three-phase radiographic unit has been fitted by an analytic function. The average accuracy of the fit between the limits of 40-140 kVp and 2.5- to 6.0-mm aluminum filtration was 0.3%. The concept of linear scaling was employed to allow the analytic function to accurately reproduce the exposure outputs of different radiographic units. Validation experiments on patients indicated that an overall accuracy of 10% can be expected when using well-calibrated radiographic equipment. The method described permits institutions to verify their compliance with federal and/or state regulations and to confirm that their radiation exposures are consistent with national averages.
Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
Radiat Prot DosimetryHome page
G. Compagnone, L. Pagan, and C. Bergamini
Local diagnostic reference levels in standard X-ray examinations
Radiat Prot Dosimetry, April 18, 2005; 113(1): 54 - 63.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1987 by the American Roentgen Ray Society.