AJR Join ARRS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Shellock, F.
Right arrow Articles by Crues, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Shellock, F.
Right arrow Articles by Crues, J.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
American Journal of Roentgenology, Vol 151, Issue 2, 389-392
Copyright © 1988 by American Roentgen Ray Society


Articles

High-field-strength MR imaging and metallic biomedical implants: an ex vivo evaluation of deflection forces

FG Shellock and JV Crues

Department of Medicine, Cedars-Sinai Medical Center, Los Angeles, CA 90048.

Ferromagnetic biomedical implants are considered a contraindication for MR imaging primarily because of the potential hazards associated with their movement or dislodgment. Many metallic biomedical implants are composed of nonferromagnetic materials and do not present a danger to patients during MR imaging. Therefore, to evaluate the ferromagnetic qualities of 36 different metallic biomedical implants (four aneurysm clips, six hemostatic clips, four dental implants, seven prosthetic heart valves, eight orthopedic prostheses, one artificial urinary sphincter, three contraceptive diaphragms, and three cerebral ventricular shunt tube connectors) not previously evaluated with a high-field-strength MR system, we measured deflection forces at the portal of the magnet of a 1.5-T MR system. Fourteen of the 36 metallic biomedical implants were determined to be ferromagnetic as indicated by their deflection in the static magnetic field. However, only the four aneurysm clips (Drake, Mayfield, McFadden, and Sundt-Kees) had sufficient ferromagnetism to warrant exclusion of patients with these implants from imaging with a 1.5-T MR system because of the possibility of movement or displacement. The calculated deflection forces for these aneurysm clips were comparable with previously reported values of certain aneurysm clips that have been designated to present a risk for patients undergoing MR imaging. Patients with 32 of 36 metallic biomedical implants tested can be safely imaged with high-field-strength MR systems.
Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
Am. J. Neuroradiol.Home page
F. G. Shellock, J. A. Tkach, P. M. Ruggieri, T. J. Masaryk, and P. A. Rasmussen
Aneurysm Clips: Evaluation of Magnetic Field Interactions and Translational Attraction by Use of "Long-Bore" and "Short-Bore" 3.0-T MR Imaging Systems
AJNR Am. J. Neuroradiol., March 1, 2003; 24(3): 463 - 471.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
F. G. Shellock and J. V. Crues III
MR Safety and the American College of Radiology White Paper
Am. J. Roentgenol., June 1, 2002; 178(6): 1349 - 1352.
[Full Text] [PDF]


Home page
RadiologyHome page
C. T. Hennemeyer, K. Wicklow, D. A. Feinberg, and C. P. Derdeyn
In Vitro Evaluation of Platinum Guglielmi Detachable Coils at 3 T with a Porcine Model: Safety Issues and Artifacts
Radiology, June 1, 2001; 219(3): 732 - 737.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
J. Hug, E. Nagel, A. Bornstedt, B. Schnackenburg, H. Oswald, and E. Fleck
Coronary Arterial Stents: Safety and Artifacts during MR Imaging
Radiology, September 1, 2000; 216(3): 781 - 787.
[Abstract] [Full Text]


Home page
RadiologyHome page
E. Kanal, C. C. Meltzer, P. D. Adelson, and M. P. Scheuer
Platinum Subdural Grid: MR Imaging Compatibility Testing
Radiology, June 1, 1999; 211(3): 886 - 888.
[Abstract] [Full Text]


Home page
RadiologyHome page
E. Kanal and F. G. Shellock
Aneurysm Clips: Effects of Long-term and Multiple Exposures to a 1.5-T MR System
Radiology, February 1, 1999; 210(2): 563 - 565.
[Abstract] [Full Text]