AJR Join ARRS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Sutton, C.
Right arrow Articles by Nose, Y
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Sutton, C.
Right arrow Articles by Nose, Y
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
American Journal of Roentgenology, Vol 151, Issue 3, 597-601
Copyright © 1988 by American Roentgen Ray Society


Articles

Titanium-nickel intravascular endoprosthesis: a 2-year study in dogs

CS Sutton, T Oku, H Harasaki, HE Kambic, Y Sugita, S Murabayashi, E Shirey, and Y Nose

Department of Artificial Organs, Cleveland Foundation, OH 44106.

Twelve 5-mm-internal-diameter intravascular endoprostheses of noncorrosive, shape-memory titanium-nickel (TiNi) alloy were delivered transluminally by catheter and implanted in the iliac (n = 10) and femoral (n = 2) arteries of six normal dogs for either 1 or 2 years in order to evaluate the implantation technique and long-term effects. The patency rates were as follows: at 1 month, 92% (11/12); at 1 year, 100% 11/12 widely patent; 1/12 recanalized); and at 2 years, 100% (3/4 without stenosis; 1/4 with 20% stenosis). No migration, erosion, inflammation, surface thrombus, or stenosis of the side branches was seen; an absence of untoward angiographic and histopathologic effects was detected at 1 and 2 years. The neointima was completely endothelialized, without changes in thickness over time, 229.3 +/- 127.6 microns after 1 year and 223.3 +/- 216.7 microns after 2 years (p = not significant). The neointimal layer became thicker toward its distal aspect (p less than or equal to .05). Satisfactory delivery, long-term patency, and biocompatibility (manifested as a thin, stable neointima) were observed for the TiNi intravascular endoprosthesis at 1 and 2 years.
Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1988 by the American Roentgen Ray Society.