AJR Women's Imaging Online
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by vanSonnenberg, E
Right arrow Articles by Mattrey, R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by vanSonnenberg, E
Right arrow Articles by Mattrey, R.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
American Journal of Roentgenology, Vol 151, Issue 4, 815-817
Copyright © 1988 by American Roentgen Ray Society


Articles

A wire-sheath system for MR-guided biopsy and drainage: laboratory studies and experience in 10 patients

E vanSonnenberg, P Hajek, V Gylys-Morin, RA Varney, L Baker, G Casola, R Christensen, and RF Mattrey

Department of Radiology, University of California, San Diego, Medical Center 92103.

On the basis of laboratory experiments, we devised a wire-sheath system for MR-guided biopsy and drainage and then evaluated that system in 10 patients. The localizing system consisted of a 20-gauge plastic sheath into which a stainless-steel alloy wire had been inserted. In laboratory studies, we compared this wire-sheath assembly with other materials to determine its optimal visualization on MR images. We then used the same wire-sheath system to perform 16 procedures (in 10 patients), including six biopsies, five diagnostic fluid aspirations, and five catheter drainages of infected and noninfected fluid collections. The laboratory results showed that the wire-sheath assembly cast a 7-mm artifact, was visualized well on all pulse sequences, and was safe within the magnet (minimal attraction). The assembly was visualized well in each patient and provided adequate localization. MR-guided biopsy and drainage can be performed with high-resolution detail by using this wire-sheath system. Potential uses of this system include (1) treatment of lesions that can be seen on MR images only (or that can be seen to significantly better advantage on MR images than on sonograms or CT scans), and (2) treatment of patients in whom avoidance of the radiation delivered by CT is imperative.
Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1988 by the American Roentgen Ray Society.