AJR Your Link to CME
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Hayrapetian, A
Right arrow Articles by Boechat, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Hayrapetian, A
Right arrow Articles by Boechat, M.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
American Journal of Roentgenology, Vol 152, Issue 5, 1113-1118
Copyright © 1989 by American Roentgen Ray Society


Articles

Comparison of 2048-line digital display formats and conventional radiographs: an ROC study

A Hayrapetian, DR Aberle, HK Huang, R Fiske, C Morioka, D Valentino, and MI Boechat

Department of Radiological Sciences, UCLA Medical Center 90024-1721.

Observer performance tests were conducted to compare the effects on diagnostic accuracy of digital hard copy and video display formats versus conventional radiographic film. Digital images were obtained by digitizing conventional chest radiographs to a 2048 x 2048 matrix with a laser film scanner. Three digital display formats were used: laser-printed digital film, a 2048-line video monitor without user interaction, and a 2048-line video monitor with user interaction. Thirty-one posteroanterior chest radiographs, determined by consensus of four thoracic radiologists to contain septal lines (n = 11), parenchymal nodules (n = 7), nodules and septal lines (n = 7), or neither abnormality (n = 6), were used for the study. Images were interpreted by four radiologists in four separate viewing sessions. Diagnostic accuracy was determined by receiver-operating characteristic analysis for each observer with each viewing technique. No statistical differences in diagnostic accuracy, determined by the area under the receiver-operating-characteristic curve, were found between the analog film, the digital film, and the two video digital display formats. This preliminary study suggests that 2048-line digital displays may be an acceptable alternative to the traditional lightbox viewing method for the perception of these two abnormalities commonly seen on chest radiographs.
Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
RadiologyHome page
T. S. Kim, J.-G. Im, J. M. Goo, K. H. Lee, Y.-J. Lee, S. H. Kim, and S. Kim
Detection of Pulmonary Edema in Pigs: Storage Phosphor versus Amorphous Selenium-based Flat-Panel-Detector Radiography
Radiology, June 1, 2002; 223(3): 695 - 701.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
J. Eng, W. K. Mysko, G. E. R. Weller, R. Renard, J. N. Gitlin, D. A. Bluemke, D. Magid, G. D. Kelen, and W. W. Scott Jr.
Interpretation of Emergency Department Radiographs: A Comparison of Emergency Medicine Physicians with Radiologists, Residents with Faculty, and Film with Digital Display
Am. J. Roentgenol., November 1, 2000; 175(5): 1233 - 1238.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
J. M. Goo, J.-G. Im, J. H. Kim, J. B. Seo, T. S. Kim, S. J. Shine, and W. Lee
Digital Chest Radiography with a Selenium-Based Flat-Panel Detector Versus a Storage Phosphor System: Comparison of Soft-Copy Images
Am. J. Roentgenol., October 1, 2000; 175(4): 1013 - 1018.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
B. Graf, U. Simon, F. Eickmeyer, and V. Fiedler
IK Versus 2K Monitor: A Clinical Alternative Free-Response Receiver Operating Characteristic Study of Observer Performance Using Pulmonary Nodules
Am. J. Roentgenol., April 1, 2000; 174(4): 1067 - 1074.
[Abstract] [Full Text] [PDF]


Home page
BMJHome page
P. A. Halvorsen and I. S. Kristiansen
Radiology services for remote communities: cost minimisation study of telemedicine
BMJ, May 25, 1996; 312(7042): 1333 - 1336.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1989 by the American Roentgen Ray Society.