AJR ARRS PQI
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Baron, R.
Right arrow Articles by Nelson, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Baron, R.
Right arrow Articles by Nelson, J.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
Hotlight (NEW!)
Right arrow
What's Hotlight?
American Journal of Roentgenology, Vol 153, Issue 3, 497-502
Copyright © 1989 by American Roentgen Ray Society


Articles

MR appearance of gallstones in vitro at 1.5 T: correlation with chemical composition

RL Baron, WP Shuman, SP Lee, CA Rohrmann Jr, RN Golden, TL Richards, ML Richardson, and JA Nelson

Department of Radiology, University of Washington School of Medicine, Seattle 98195.

Gallstones from 63 patients were evaluated by in vitro 1.5-T MR imaging, with T1- and T2-weighted images, and in 14 cases, a fat-suppression sequence (short-T1 inversion recovery imaging). Subsequent chemical analysis was performed on 43 gallstones. In vitro proton MR spectroscopy was performed on 14 stones. On T1-weighted MR images, foci of increased signal were seen in 46 of 63 stones (faint in 17, moderate in nine, and bright in 20). T2-weighted images showed areas of increased signal in 18 of 63 stones (faint in 15, moderate in three). T1-weighted MR imaging patterns were homogeneously dark (17), homogeneously bright (two), homogeneously faint (three), rimmed (dark rim and bright center, 32), and laminated (nine). Short-T1 inversion recovery imaging suppressed the foci of increased signal in 13 of 14 cases. Despite imaging characteristics suggestive of high lipid content, spectroscopy revealed only a single peak corresponding to a large water-proton signal. The T1 relaxation times of the water were shortened, ranging from 0.006 to 0.92 sec, explaining the increased signal seen on MR images of the gallstones. MR imaging characteristics (signal intensity, relative signal area, or imaging patterns) did not correlate with chemical composition. We hypothesize that different structural relationships must exist within gallstones of similar chemical content that alter the water bonding and hence the MR imaging characteristics.
Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
RadioGraphicsHome page
B. M. Yeh, P. S. Liu, J. A. Soto, C. A. Corvera, and H. K. Hussain
MR Imaging and CT of the Biliary Tract
RadioGraphics, October 1, 2009; 29(6): 1669 - 1688.
[Abstract] [Full Text] [PDF]


Home page
RadioGraphicsHome page
O. A. Catalano, D. V. Sahani, S. P. Kalva, M. S. Cushing, P. F. Hahn, J. J. Brown, and R. R. Edelman
MR Imaging of the Gallbladder: A Pictorial Essay
RadioGraphics, January 1, 2008; 28(1): 135 - 155.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
H.-M. Tsai, X.-Z. Lin, C.-Y. Chen, P.-W. Lin, and J.-C. Lin
MRI of Gallstones with Different Compositions
Am. J. Roentgenol., June 1, 2004; 182(6): 1513 - 1519.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1989 by the American Roentgen Ray Society.