AJR Your Link to CME
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Daniel, T. B.
Right arrow Articles by Hawkins, I. F.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Daniel, T. B.
Right arrow Articles by Hawkins, I. F., Jr
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?

American Journal of Roentgenology, Vol 154, 1091-1095, Copyright © 1990 by American Roentgen Ray Society


ARTICLES

A solution to the problem of high-flow jets from miniature angiographic catheters

TB Daniel, EW Akins and IF Hawkins Jr
Department of Radiology, University of Florida College of Medicine, Gainesville, FL 32610-0374.

In this study we evaluated methods for reducing high-flow jets from 5- French catheters that occur when injection pressures approach catheter tolerance (1000 psi [6.9 MPa]). This "jet effect" has been responsible for subintimal extravasation of contrast material in patients. We designed a physical model that accurately measures flow rates through the end hole and each side hole of 5-French high-flow catheters under simulated physiologic arterial pressure. When a standard catheter commonly used for injection of contrast material was studied, flow of contrast material was 34% through the end hole and 31% through the distal side-hole pair at high injection pressures (1000 psi). We examined the effect of altering the size and configuration of catheter side holes and end hole in an effort to create an improved flow profile, and thus a safer angiographic catheter. End-hole flow rate was reduced by 73% to 9% of total flow by tapering the 5-French catheter to 0.018 in. (0.046 cm) and by using smaller 0.015-in. (0.038-cm) side holes for even flow distribution. The high-flow jets present with standard high-flow 5-French catheters do not occur when flow- restrictive end holes and side holes are used. A uniform flow profile can be obtained without sacrificing delivery of contrast material through small catheters.