AJR ARRS Membership
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Lofgren, M.
Right arrow Articles by Lindholm, K.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Lofgren, M.
Right arrow Articles by Lindholm, K.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?

American Journal of Roentgenology, Vol 154, 1191-1195, Copyright © 1990 by American Roentgen Ray Society


ARTICLES

Stereotactic fine-needle aspiration for cytologic diagnosis of nonpalpable breast lesions

M Lofgren, I Andersson and K Lindholm
Department of Diagnostic Radiology, Malmo General Hospital, University of Lund, Sweden.

Fine-needle aspiration for cytologic diagnosis was performed on 219 nonpalpable breast lesions by using a stereotactic localization technique. Cytologic results were correlated with mammographic findings, and therapeutic decisions were based on the results of both procedures. Representative cytologic material was obtained in 74% of the lesions. Strict criteria of representativeness were observed. If only cases with representative cytologic yield are considered, the sensitivity was 93% and the specificity was 97%. The predictive values were high except for the predictive value of a negative cytologic finding in a spiculated lesion (50%). Sampling errors caused by abundant fibrosis, needle deviation, and difficulty in defining the lesion on the stereoscopic views are discussed. Another source of sampling error may be the mixed nature of some lesions consisting of benign and malignant components. Fine-needle aspiration of 219 nonpalpable breast lesions by using a stereotactic localization device yielded representative cytologic samples in 74% of the lesions.
Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
RadiologyHome page
E. D. Pisano, L. L. Fajardo, D. J. Caudry, N. Sneige, W. J. Frable, W. A. Berg, I. Tocino, S. J. Schnitt, J. L. Connolly, C. A. Gatsonis, et al.
Fine-Needle Aspiration Biopsy of Nonpalpable Breast Lesions in a Multicenter Clinical Trial: Results from the Radiologic Diagnostic Oncology Group V
Radiology, June 1, 2001; 219(3): 785 - 792.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1990 by the American Roentgen Ray Society.