Diagnostic accuracy of contrast-enhanced CT, unenhanced MR imaging, and MR images enhanced with superparamagnetic iron oxide was evaluated in 10 patients with histologically proved hepatic metastases. First, diagnostic performance of the imaging technique with respect to the ability of radiologists to recognize the presence or absence of a metastasis was measured by using receiver-operating-characteristic (ROC) analysis of single images. Second, the total number of lesions (N = 108) detected by "complete" CT and MR examinations was counted. Finally, lesion-liver contrast-to-noise ratios (CNR) were measured in all MR sequences. The area under the ROC curve was .67 +/- .03 for contrast-enhanced CT, .81 +/- .07 for the unenhanced SE 260/14 sequence, and .92 +/- .01 for the iron oxide-enhanced SE 1500/40 sequence. The enhanced SE 1500/40 sequence yielded significantly (p less than .005) greater accuracy than did contrast-enhanced CT. The same sequence detected significantly (p less than .05) more lesions than all other imaging techniques (19% more than the best unenhanced MR sequence and 36% more than contrast-enhanced CT). The enhanced SE 1500/40 sequence also yielded the highest CNR value (19.5 +/- 10.2) of all MR sequences. These results indicate that iron oxide-enhanced MR imaging is a superior imaging technique for the detection of hepatic lesions.
This article has been cited by other articles:
![]() |
H. Onishi, T. Murakami, T. Kim, M. Hori, R. Iannaccone, M. Kuwabara, H. Abe, S. Nakata, K. Osuga, K. Tomoda, et al. Hepatic Metastases: Detection with Multi-Detector Row CT, SPIO-enhanced MR Imaging, and Both Techniques Combined Radiology, April 1, 2006; 239(1): 131 - 138. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. Ward, P. J. Robinson, J. A. Guthrie, S. Downing, D. Wilson, J. P. A. Lodge, K. R. Prasad, G. J. Toogood, and J. I. Wyatt Liver Metastases in Candidates for Hepatic Resection: Comparison of Helical CT and Gadolinium- and SPIO-enhanced MR Imaging Radiology, October 1, 2005; 237(1): 170 - 180. [Abstract] [Full Text] [PDF] |
||||
![]() |
Y. K. Kim, C. S. Kim, Y. H. Lee, H. S. Kwak, and J. M. Lee Comparison of Superparamagnetic Iron Oxide-Enhanced and Gadobenate Dimeglumine-Enhanced Dynamic MRI for Detection of Small Hepatocellular Carcinomas Am. J. Roentgenol., May 1, 2004; 182(5): 1217 - 1223. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. Ward, J. A. Guthrie, D. Wilson, P. Arnold, J. P. Lodge, G. J. Toogood, J. I. Wyatt, and P. J. Robinson Colorectal Hepatic Metastases: Detection with SPIO-enhanced Breath-hold MR Imaging—Comparison of Optimized Sequences Radiology, September 1, 2003; 228(3): 709 - 718. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. N. Mann, H. F. Marx, L. L. Lai, and L. D. Wagman Clinical and Cost Effectiveness of a New Hepatocellular MRI Contrast Agent, Mangafodipir Trisodium, in the Preoperative Assessment of Liver Resectability Ann. Surg. Oncol., August 1, 2001; 8(7): 573 - 579. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. Reimer, N. Jähnke, M. Fiebich, W. Schima, F. Deckers, C. Marx, N. Holzknecht, and S. Saini Hepatic Lesion Detection and Characterization: Value of Nonenhanced MR Imaging, Superparamagnetic Iron Oxide-enhanced MR Imaging, and Spiral CT-ROC Analysis Radiology, October 1, 2000; 217(1): 152 - 158. [Abstract] [Full Text] |
||||
![]() |
A. Foroutani, A. M. Garland, E. Berber, A. String, K. Engle, T. L. Ryan, J. M. Pearl, and A. E. Siperstein Laparoscopic Ultrasound vs Triphasic Computed Tomography for Detecting Liver Tumors Arch Surg, August 1, 2000; 135(8): 933 - 938. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. I. Goldberg and A. R. Margulis Gastrointestinal Radiology in the United States: An Overview of the Past 50 Years Radiology, July 1, 2000; 216(1): 1 - 7. [Abstract] [Full Text] |
||||
![]() |
E. F. Patz Jr Imaging Bronchogenic Carcinoma Chest, April 1, 2000; 117(4_suppl_1): 90S - 95S. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. Ward, F. Chen, J. A. Guthrie, D. Wilson, J. P. A. Lodge, J. I. Wyatt, and P. J. Robinson Hepatic Lesion Detection after Superparamagnetic Iron Oxide Enhancement: Comparison of Five T2-weighted Sequences at 1.0 T by Using Alternative-Free Response Receiver Operating Characteristic Analysis1 Radiology, January 1, 2000; 214(1): 159 - 166. [Abstract] [Full Text] |
||||
![]() |
J. Ward, K. S. Naik, J. A. Guthrie, D. Wilson, and P. J. Robinson Hepatic Lesion Detection: Comparison of MR Imaging after the Administration of Superparamagnetic Iron Oxide with Dual-Phase CT by Using Alternative–Free Response Receiver Operating Characteristic Analysis Radiology, February 1, 1999; 210(2): 459 - 466. [Abstract] [Full Text] |
||||