American Journal of Roentgenology, Vol 155, 943-950, Copyright © 1990 by American Roentgen Ray Society
ARTICLES |
JT Ferrucci and DD Stark
Department of Radiology, Massachusetts General Hospital, Boston.
Superparamagnetic iron oxide (SPIO) particles are a potent new class of MR contrast agents affording improved detection of hepatic and splenic neoplasms. In this report we review the development of this agent through preclinical studies and early clinical results at Massachusetts General Hospital during a 5-year investigation. SPIO particles are sequestered by normal phagocytic Kupffer cells of the reticuloendothelial system (RES) but are not retained in tumor tissue. Consequently, there is a fivefold increase in T2 relaxation between normal RES tissue and tumor, with a comparable advantage in quantitative signal-to-noise ratio, contrast-to-noise ratio, and lesion detectability in the liver and spleen on MR imaging. Increased lesion conspicuity can be exploited to decrease threshold size for lesion detection to less than 3 mm. Clinically beneficial effects occur with a variety of mildly T2-weighted spin-echo pulse sequences; gradient-echo techniques show even greater benefit after administration of SPIO. Metabolically, pharmaceutical-grade preparations are biodegradable and bioavailable, being rapidly turned over into body iron stores and incorporated into erythrocyte hemoglobin. Early dose-escalation clinical trials have identified a probable clinical dose range of 10-20 mumols Fe/kg body weight. In the United States, SPIO compounds evaluated to date are still approved for use in investigational studies only. Newer commercial formulations currently being evaluated may extend clinical safety margins.
This article has been cited by other articles:
![]() |
J. Terrovitis, M. Stuber, A. Youssef, S. Preece, M. Leppo, E. Kizana, M. Schar, G. Gerstenblith, R. G. Weiss, E. Marban, et al. Magnetic Resonance Imaging Overestimates Ferumoxide-Labeled Stem Cell Survival After Transplantation in the Heart Circulation, March 25, 2008; 117(12): 1555 - 1562. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. N. Gandhi, M. A. Brown, J. G. Wong, D. A. Aguirre, and C. B. Sirlin MR Contrast Agents for Liver Imaging: What, When, How RadioGraphics, November 1, 2006; 26(6): 1621 - 1636. [Abstract] [Full Text] [PDF] |
||||
![]() |
N. V. Evgenov, Z. Medarova, J. Pratt, P. Pantazopoulos, S. Leyting, S. Bonner-Weir, and A. Moore In Vivo Imaging of Immune Rejection in Transplanted Pancreatic Islets Diabetes, September 1, 2006; 55(9): 2419 - 2428. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. S. Arbab, G. T. Yocum, H. Kalish, E. K. Jordan, S. A. Anderson, A. Y. Khakoo, E. J. Read, and J. A. Frank Efficient magnetic cell labeling with protamine sulfate complexed to ferumoxides for cellular MRI Blood, August 15, 2004; 104(4): 1217 - 1223. [Abstract] [Full Text] [PDF] |
||||
![]() |
Y. K. Kim, C. S. Kim, Y. H. Lee, H. S. Kwak, and J. M. Lee Comparison of Superparamagnetic Iron Oxide-Enhanced and Gadobenate Dimeglumine-Enhanced Dynamic MRI for Detection of Small Hepatocellular Carcinomas Am. J. Roentgenol., May 1, 2004; 182(5): 1217 - 1223. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. S. Arbab, L. A. Bashaw, B. R. Miller, E. K. Jordan, B. K. Lewis, H. Kalish, and J. A. Frank Characterization of Biophysical and Metabolic Properties of Cells Labeled with Superparamagnetic Iron Oxide Nanoparticles and Transfection Agent for Cellular MR Imaging Radiology, December 1, 2003; 229(3): 838 - 846. [Abstract] [Full Text] [PDF] |
||||
![]() |
M.-J. Kim, J. H. Kim, J.-J. Chung, M. S. Park, J. S. Lim, and Y. T. Oh Focal Hepatic Lesions: Detection and Characterization with Combination Gadolinium- and Superparamagnetic Iron Oxide-enhanced MR Imaging Radiology, September 1, 2003; 228(3): 719 - 726. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. D. Frate, C. Zuiani, V. Londero, G. Como, M. Bazzocchi, K. Mortele, and P. R. Ros Comparing Levovist-Enhanced Pulse Inversion Harmonic Imaging and Ferumoxides-Enhanced MR Imaging of Hepatic Metastases Am. J. Roentgenol., May 1, 2003; 180(5): 1339 - 1346. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. Del Frate, M. Bazzocchi, K. J. Mortele, C. Zuiani, V. Londero, G. Como, R. Zanardi, and P. R. Ros Detection of Liver Metastases: Comparison of Gadobenate Dimeglumine-enhanced and Ferumoxides-enhanced MR Imaging Examinations Radiology, December 1, 2002; 225(3): 766 - 772. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. S. Raman, D. S. K. Lu, S. C. Chen, J. Sayre, F. Eilber, and J. Economou Hepatic MR Imaging Using Ferumoxides: Prospective Evaluation with Surgical and Intraoperative Sonographic Confirmation in 25 Cases Am. J. Roentgenol., October 1, 2001; 177(4): 807 - 812. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Hirohashi, K. Ueda, H. Uchida, W. Ono, J. Takahama, M. Takewa, S. Kitano, and H. Ohishi Nondiffuse Fatty Change of the Liver: Discerning Pseudotumor on MR Images Enhanced with Ferumoxides-Initial Observations Radiology, November 1, 2000; 217(2): 415 - 420. [Abstract] [Full Text] |
||||
![]() |
P. Reimer, N. Jähnke, M. Fiebich, W. Schima, F. Deckers, C. Marx, N. Holzknecht, and S. Saini Hepatic Lesion Detection and Characterization: Value of Nonenhanced MR Imaging, Superparamagnetic Iron Oxide-enhanced MR Imaging, and Spiral CT-ROC Analysis Radiology, October 1, 2000; 217(1): 152 - 158. [Abstract] [Full Text] |
||||
![]() |
J. Petersein, A. Spinazzi, A. Giovagnoni, P. Soyer, F. Terrier, R. Lencioni, C. Bartolozzi, L. Grazioli, A. Chiesa, R. Manfredi, et al. Focal Liver Lesions: Evaluation of the Efficacy of Gadobenate Dimeglumine in MR Imaging-A Multicenter Phase III Clinical Study Radiology, June 1, 2000; 215(3): 727 - 736. [Abstract] [Full Text] |
||||
![]() |
S. A. Schmitz, T. Albrecht, and K.-J. Wolf MR Angiography with Superparamagnetic Iron Oxide: Feasibility Study Radiology, October 1, 1999; 213(2): 603 - 607. [Abstract] [Full Text] |
||||
![]() |
K. M. Horton, D. A. Bluemke, R. H. Hruban, P. Soyer, and E. K. Fishman CT and MR Imaging of Benign Hepatic and Biliary Tumors RadioGraphics, March 1, 1999; 19(2): 431 - 451. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. Ward, K. S. Naik, J. A. Guthrie, D. Wilson, and P. J. Robinson Hepatic Lesion Detection: Comparison of MR Imaging after the Administration of Superparamagnetic Iron Oxide with Dual-Phase CT by Using Alternative–Free Response Receiver Operating Characteristic Analysis Radiology, February 1, 1999; 210(2): 459 - 466. [Abstract] [Full Text] |
||||
![]() |
R. R. Edelman and S. Warach Magnetic Resonance Imaging- Second of Two Parts N. Engl. J. Med., March 18, 1993; 328(11): 785 - 791. [Full Text] |
||||
![]() |
D. Pauleit, J. Textor, R. Bachmann, R. Conrad, S. Flacke, G. Layer, B. Kreft, and H. Schild Hepatocellular Carcinoma: Detection with Gadolinium- and Ferumoxides-enhanced MR Imaging of the Liver Radiology, January 1, 2002; 222(1): 73 - 80. [Abstract] [Full Text] [PDF] |
||||