AJR InPractice
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Fernandez, M. P.
Right arrow Articles by Olson, R. A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Fernandez, M. P.
Right arrow Articles by Olson, R. A.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
Hotlight (NEW!)
Right arrow
What's Hotlight?

American Journal of Roentgenology, Vol 156, 1171-1176, Copyright © 1991 by American Roentgen Ray Society


ARTICLES

Diagnosis of pancreatic transplant dysfunction: value of gadopentetate dimeglumine-enhanced MR imaging

MP Fernandez, ME Bernardino, JF Neylan and RA Olson
Department of Radiology, Emory University School of Medicine, Atlanta, GA 30322.

Sixteen MR studies performed in four patients who had undergone combined pancreatic and renal transplantation were reviewed retrospectively to determine if dynamic gadopentetate dimeglumine- enhanced gradient-echo imaging is useful in the early diagnosis of pancreatic transplant rejection. The MR studies were performed between 3 days and 6 months after transplantation and consisted of T1- and T2- weighted spin-echo images as well as a gradient-echo image prior to administration of an IV bolus of gadopentetate dimeglumine (0.1 mmol/kg). After injection of gadopentetate dimeglumine, a static dynamic gradient-echo scan was obtained. Signal-intensity measurements were determined for each of the gradient-echo images and used to generate an enhancement curve. Because T2 values have previously been used as an objective indicator of rejection, the mean T2 of each pancreatic transplant was calculated also. The MR results were compared with clinical and laboratory data and/or percutaneous biopsy results. In six studies of normally functioning pancreatic allografts, the percent enhancement during the first minute of the enhancement curve was 98 +/- 23% (1 SD). In six episodes of acute dysfunction (rejection or infarction), the first-minute enhancement was 42 +/- 20%. In four cases of dysfunction, the finding of an abnormal enhancement curve preceded a significant drop in urinary amylase by 1-4 days. The calculated T2 value was prolonged in only two cases in which biopsy- proved pancreatic infarction had occurred. No prolongation of T2 was evident in four cases of rejection alone. These results suggest that mean T2 calculation at 1.5 T may not be a reliable indicator of pancreatic transplant rejection, but that gadopentetate dimeglumine- enhanced gradient-echo MR imaging of the pancreatic transplant may be a reliable early indicator of pancreatic transplant dysfunction.
Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
RadiologyHome page
K. D. Hagspiel, K. Nandalur, T. L. Pruett, D. A. Leung, J. F. Angle, D. J. Spinosa, A. H. Matsumoto, H. Ahmed, H. A. Sanfey, R. G. Sawyer, et al.
Evaluation of Vascular Complications of Pancreas Transplantation with High-Spatial-Resolution Contrast-enhanced MR Angiography
Radiology, February 1, 2007; 242(2): 590 - 599.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
J. T. Heverhagen, H.-J. Wagner, H. Ebel, A. L. Levine, K. J. Klose, and A. Hellinger
Pancreatic Transplants: Noninvasive Evaluation with Secretin-augmented MR Pancreatography and MR Perfusion Measurements--Preliminary Results
Radiology, October 1, 2004; 233(1): 273 - 280.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
M. C. Freund, W. Steurer, E. M. Gassner, K. M. Unsinn, M. Rieger, A. Koenigsrainer, R. Margreiter, and W. R. Jaschke
Spectrum of Imaging Findings After Pancreas Transplantation with Enteric Exocrine Drainage: Part 2, Posttransplantation Complications
Am. J. Roentgenol., April 1, 2004; 182(4): 919 - 925.
[Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
W. B. Eubank, U. P. Schmiedl, A. E. Levy, and C. L. Marsh
Venous Thrombosis and Occlusion After Pancreas Transplantation: Evaluation with Breath-Hold Gadolinium-Enhanced Three-Dimensional MR Imaging
Am. J. Roentgenol., August 1, 2000; 175(2): 381 - 385.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
T. L. Krebs, B. Daly, J. J. Wong-You-Cheong, K. Carroll, and S. T. Bartlett
Acute Pancreatic Transplant Rejection: Evaluation with Dynamic Contrast-enhanced MR Imaging Compared with Histopathologic Analysis
Radiology, February 1, 1999; 210(2): 437 - 442.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1991 by the American Roentgen Ray Society.