AJR Join ARRS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kondo, C.
Right arrow Articles by Higgins, C. B.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kondo, C.
Right arrow Articles by Higgins, C. B.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?

American Journal of Roentgenology, Vol 157, 9-16, Copyright © 1991 by American Roentgen Ray Society


ARTICLES

Right and left ventricular stroke volume measurements with velocity- encoded cine MR imaging: in vitro and in vivo validation

C Kondo, GR Caputo, R Semelka, E Foster, A Shimakawa and CB Higgins
Department of Radiology, University of California Medical Center, San Francisco 94143.

The accuracy of measurements of flow velocity determined by using cine MR phase velocity mapping--velocity-encoded cine (VEC) MR--was assessed by comparing VEC MR data with independent measurements in a flow phantom and in human subjects. Constant flow velocities generated in a phantom (range, 20-408 cm/sec) were determined correctly by VEC MR (r = .997, standard error of the estimate [SEE] = 7.9 cm/sec). Peak systolic velocities in the main pulmonary artery determined by VEC MR correlated well with the measurements obtained by using continuous-wave Doppler echocardiography (r = .91). Stroke volumes measured at the aorta by VEC MR and continuous-wave Doppler imaging also correlated well with each other (r = .80). VEC MR measurements of aortic and pulmonary flow provided left and right ventricular stroke volumes that correlated well with left ventricular stroke volumes determined by short-axis cine MR images (r = .98, SEE = 3.7 ml, and r = .95, SEE = 4.8 ml, respectively). Intra- and interobserver variabilities were small for both left and right ventricular stroke volumes as measured with VEC MR. These results indicate that VEC MR accurately and reproducibly measures aortic and pulmonary flow velocities and volumes in the physiologic range of humans, and can be used to measure right and left ventricular stroke volumes under normal flow conditions.
Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
HeartHome page
G. F Greil, P. Beerbaum, R. Razavi, and O. Miller
Imaging the right ventricle: Non-invasive imaging
Heart, June 1, 2008; 94(6): 803 - 808.
[Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
S. Ley, C. Fink, M. Puderbach, J. Zaporozhan, C. Plathow, M. Eichinger, W. Hosch, K.-F. Kreitner, and H.-U. Kauczor
MRI Measurement of the hemodynamics of the pulmonary and systemic arterial circulation: influence of breathing maneuvers.
Am. J. Roentgenol., August 1, 2006; 187(2): 439 - 444.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
S Sridharan, G Derrick, J Deanfield, and A M Taylor
Assessment of differential branch pulmonary blood flow: a comparative study of phase contrast magnetic resonance imaging and radionuclide lung perfusion imaging.
Heart, July 1, 2006; 92(7): 963 - 968.
[Abstract] [Full Text] [PDF]


Home page
RadioGraphicsHome page
K. I. Norton, C. Tong, R. B. J. Glass, and J. C. Nielsen
Cardiac MR Imaging Assessment Following Tetralogy of Fallot Repair
RadioGraphics, January 1, 2006; 26(1): 197 - 211.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
A. Lembcke, A. C. Borges, S. Dushe, P. M. Dohmen, T. H. Wiese, P. Rogalla, K.-G. A. Hermann, B. Hamm, and C. N. H. Enzweiler
Assessment of Mitral Valve Regurgitation at Electron-Beam CT: Comparison with Doppler Echocardiography
Radiology, July 1, 2005; 236(1): 47 - 55.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
D. J. Pennell, U. P. Sechtem, C. B. Higgins, W. J. Manning, G. M. Pohost, F. E. Rademakers, A. C. van Rossum, L. J. Shaw, and E. K. Yucel
Clinical indications for cardiovascular magnetic resonance (CMR): Consensus Panel report
Eur. Heart J., November 1, 2004; 25(21): 1940 - 1965.
[Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
J. Albers, T. Nitsche, J. Boese, R. De Simone, I. Wolf, A. Schroeder, and C. F. Vahl
Regurgitant jet evaluation using three-dimensional echocardiography and magnetic resonance
Ann. Thorac. Surg., July 1, 2004; 78(1): 96 - 102.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
I-S. Kang, A. N. Redington, L. N. Benson, C. Macgowan, E. R. Valsangiacomo, K. Roman, C. J. Kellenberger, and S.-J. Yoo
Differential Regurgitation in Branch Pulmonary Arteries After Repair of Tetralogy of Fallot: A Phase-Contrast Cine Magnetic Resonance Study
Circulation, June 17, 2003; 107(23): 2938 - 2943.
[Abstract] [Full Text] [PDF]


Home page
RadioGraphicsHome page
J. Lotz, C. Meier, A. Leppert, and M. Galanski
Cardiovascular Flow Measurement with Phase-Contrast MR Imaging: Basic Facts and Implementation
RadioGraphics, May 1, 2002; 22(3): 651 - 671.
[Abstract] [Full Text] [PDF]


Home page
Eur Respir JHome page
N.L. Muller
Computed tomography and magnetic resonance imaging: past, present and future
Eur. Respir. J., February 1, 2002; 19(35_suppl): 3S - 12s.
[Abstract] [Full Text] [PDF]


Home page
StrokeHome page
D. R. Rutgers, J. D. Blankensteijn, and J. van der Grond
Preoperative MRA Flow Quantification in CEA Patients : Flow Differences Between Patients Who Develop Cerebral Ischemia and Patients Who Do Not Develop Cerebral Ischemia During Cross-Clamping of the Carotid Artery
Stroke, December 1, 2000; 31(12): 3021 - 3028.
[Abstract] [Full Text] [PDF]


Home page
RadioGraphicsHome page
D. Didier, O. Ratib, R. Lerch, and B. Friedli
Detection and Quantification of Valvular Heart Disease with Dynamic Cardiac MR Imaging
RadioGraphics, September 1, 2000; 20(5): 1279 - 1299.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
N. Hirabuki, Y. Watanabe, T. Mano, N. Fujita, H. Tanaka, T. Ueguchi, and H. Nakamura
Quantitation of Flow in the Superior Sagittal Sinus Performed with Cine Phase-contrast MR Imaging of Healthy and Achondroplastic Children
AJNR Am. J. Neuroradiol., August 1, 2000; 21(8): 1497 - 1501.
[Abstract] [Full Text]


Home page
RadiologyHome page
E. Mousseaux, J. P. Tasu, O. Jolivet, G. Simonneau, J. Bittoun, and J.-C. Gaux
Pulmonary Arterial Resistance: Noninvasive Measurement with Indexes of Pulmonary Flow Estimated at Velocity-encoded MR Imaging-Preliminary Experience
Radiology, September 1, 1999; 212(3): 896 - 902.
[Abstract] [Full Text]


Home page
RadiologyHome page
H. Arheden, C. Holmqvist, U. Thilen, K. Hanséus, G. Björkhem, O. Pahlm, S. Laurin, and F. Ståhlberg
Left-to-Right Cardiac Shunts: Comparison of Measurements Obtained with MR Velocity Mapping and with Radionuclide Angiography
Radiology, May 1, 1999; 211(2): 453 - 458.
[Abstract] [Full Text]


Home page
CirculationHome page
E. Be'eri, S. E. Maier, M. J. Landzberg, T. Chung, and T. Geva
In Vivo Evaluation of Fontan Pathway Flow Dynamics by Multidimensional Phase-Velocity Magnetic Resonance Imaging
Circulation, December 22, 1998; 98(25): 2873 - 2882.
[Abstract] [Full Text] [PDF]


Home page
StrokeHome page
R. Vanninen, K. Koivisto, H. Tulla, H. Manninen, and K. Partanen
Hemodynamic Effects of Carotid Endarterectomy by Magnetic Resonance Flow Quantification
Stroke, January 1, 1995; 26(1): 84 - 89.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1991 by the American Roentgen Ray Society.