AJR Your Link to CME
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Tessler, F. N.
Right arrow Articles by Grant, E. G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Tessler, F. N.
Right arrow Articles by Grant, E. G.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?

American Journal of Roentgenology, Vol 157, 293-296, Copyright © 1991 by American Roentgen Ray Society


ARTICLES

Diagnosis of portal vein thrombosis: value of color Doppler imaging

FN Tessler, BJ Gehring, AS Gomes, RR Perrella, N Ragavendra, RW Busuttil and EG Grant
Department of Radiological Sciences, UCLA School of Medicine 90024-6904.

This study was undertaken to determine the accuracy of color Doppler imaging in the diagnosis of portal vein thrombosis. Two hundred fifteen patients were studied with color Doppler imaging to determine patency of the main portal vein. Sonographic findings were confirmed in 75 patients, aged 19 to 66 years. Correlation with angiography was obtained in 13 patients, and surgical correlation was obtained in the remaining 62. Nine patients had portal vein thrombosis on the basis of these gold standards. Sonograms were classified as showing either patency or thrombosis, depending on the ability to show color flow within the main portal vein. Agreement between sonography and angiography or surgery was found in 69 patients (61 patent, eight thrombosed). One patient with a patent portal vein at sonography was found to have a thrombosed vessel at surgery, whereas five patients without portal venous flow at sonography had patent vessels at angiography (one patient) or surgery (four patients). Overall sensitivity and specificity for detection of portal vein thrombosis were 89% and 92%, with an accuracy of 92%, a false-negative rate of 0.11, a negative predictive value of 0.98, and a positive predictive value of 0.62. We postulate that the majority of errors in our study occurred in vessels that, although patent, had only sluggish flow, which could not be resolved because of technical limitations. We conclude that color Doppler imaging is a valuable screening procedure for the assessment of portal vein patency. If the sonogram shows a patent portal vein, no further studies are required. However, a lack of demonstrable flow does not always indicate thrombosis, and other imaging studies should be performed for confirmation.
Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
Am. J. Roentgenol.Home page
S. Rossi, L. Rosa, V. Ravetta, A. Cascina, P. Quaretti, A. Azzaretti, P. Scagnelli, C. Tinelli, P. Dionigi, and F. Calliada
Contrast-enhanced versus conventional and color Doppler sonography for the detection of thrombosis of the portal and hepatic venous systems.
Am. J. Roentgenol., March 1, 2006; 186(3): 763 - 773.
[Abstract] [Full Text] [PDF]


Home page
J Ultrasound MedHome page
J.-H. Yoon, S.-S. Han, S.-S. Cha, and S.-J. Lee
Color Doppler Ultrasonography of a Pancreatic Arteriovenous Malformation
J. Ultrasound Med., January 1, 2005; 24(1): 113 - 117.
[Full Text] [PDF]


Home page
J Ultrasound MedHome page
E. G. Grant, L. L. Barr, J. Borgstede, G. A.W. Gooding, U. M. Hamper, B. S. Hertzberg, M. Horrow, R. A. Kane, F. Kremkau, J. W. Meilstrup, et al.
AIUM Standard for the Performance of an Ultrasound Examination of the Abdomen or Retroperitoneum
J. Ultrasound Med., October 1, 2002; 21(10): 1182 - 1187.
[Abstract] [Full Text] [PDF]


Home page
ImagingHome page
A S Shaw, S M Ryan, R C Beese, S Norris, M Bowles, M Rela, and P S Sidhu
Liver transplantation
Imaging, August 1, 2002; 14(4): 314 - 328.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
P. Schiedermaier, G. Layer, and T. Sauerbruch
Impact of the Continuous Infusion of Levovist on Color Doppler Sonography in Portal Hypertension
Am. J. Roentgenol., January 1, 2002; 178(1): 61 - 65.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
G. Brancatelli, M. P. Federle, K. Pealer, and D. A. Geller
Portal Venous Thrombosis or Sclerosis in Liver Transplantation Candidates: Preoperative CT Findings and Correlation with Surgical Procedure
Radiology, August 1, 2001; 220(2): 321 - 328.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
J. H. Kim, Y. S. Lee, S. H. Kim, S.-K. Lee, M. K. Lim, and H. S. Kim
Does Umbilical Vein Catheterization Lead to Portal Venous Thrombosis? Prospective US Evaluation in 100 Neonates
Radiology, June 1, 2001; 219(3): 645 - 650.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1991 by the American Roentgen Ray Society.