AJR Join ARRS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Yao, L.
Right arrow Articles by Seeger, L. L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Yao, L.
Right arrow Articles by Seeger, L. L.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?

American Journal of Roentgenology, Vol 158, 339-345, Copyright © 1992 by American Roentgen Ray Society


ARTICLES

MR imaging of joints: analytic optimization of GRE techniques at 1.5 T

L Yao, S Sinha and LL Seeger
Department of Radiological Sciences, University of California, Los Angeles 90024.

To clarify the choice of imaging parameters for optimal gradient- recalled echo MR scanning of joints, we analyzed the behavior of contrast-to-noise and signal-to-noise ratios for spoiled (i.e., fast low-angle shot [FLASH] or spoiled GRASS) and steady-state (i.e., gradient-recalled acquisition in the steady state [GRASS] or fast imaging with steady precession) techniques at 1.5 T. The analysis is based on tissue characteristics derived from spin-echo measurements of hyaline cartilage and synovial fluid signal in the patellofemoral joints of 11 volunteers. Separate analysis of contrast-to-noise and signal-to-noise ratios for multiplanar (long TR) acquisitions shows that these parameters are each improved compared with single-slice methods. At TRs greater than 250 msec, there is no significant difference in the contrast behavior of FLASH and GRASS. For optimal contrast-to-noise ratio (synovial fluid-cartilage), the best multiplanar sequence (for TE less than 23 msec) is with a short TE and a large flip angle (e.g., 400/9/73 degrees [TR/TE/flip angle]). If a single-scan or three-dimensional technique is desired, than a GRASS sequence at minimal TR and TE and intermediate flip angle (18/9/32 degrees) is best. For optimal signal-to-noise ratio (for both synovial fluid and hyaline cartilage), the best multiplanar sequence uses a short TE and an intermediate flip angle (e.g., 400/9/30 degrees). If a short TR, high signal-to-noise technique is desired, then GRASS (18/9/13 degrees) is superior to FLASH.
Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
Am. J. Roentgenol.Home page
G. E. Gold, E. Han, J. Stainsby, G. Wright, J. Brittain, and C. Beaulieu
Musculoskeletal MRI at 3.0 T: Relaxation Times and Image Contrast
Am. J. Roentgenol., August 1, 2004; 183(2): 343 - 351.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
U. Duvvuri, S. R. Charagundla, S. B. Kudchodkar, J. H. Kaufman, J. B. Kneeland, R. Rizi, J. S. Leigh, and R. Reddy
Human Knee: In Vivo T1{rho}-weighted MR Imaging at 1.5 T—Preliminary Experience
Radiology, September 1, 2001; 220(3): 822 - 826.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1992 by the American Roentgen Ray Society.