AJR ARRS: Your Link to CME
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Wiener, S. N.
Right arrow Articles by Seitz, W. H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Wiener, S. N.
Right arrow Articles by Seitz, W. H., Jr
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
Hotlight (NEW!)
Right arrow
What's Hotlight?

American Journal of Roentgenology, Vol 160, 103-107, Copyright © 1993 by American Roentgen Ray Society


ARTICLES

Sonography of the shoulder in patients with tears of the rotator cuff: accuracy and value for selecting surgical options

SN Wiener and WH Seitz Jr
Department of Radiology, Mt. Sinai Medical Center, Cleveland, OH 44106.

OBJECTIVE. The management of patients with signs and symptoms referable to the rotator cuff depends on the presence of cuff injury and the size of the tear. Treatment options include conservative nonsurgical management for patients with an intact or partially torn cuff, arthroscopic decompression of the coracoacromial space for those not responding to nonsurgical management, and a range of surgical techniques to repair full-thickness tears. This study was designed to determine whether sonographic evaluation with classification of the extent of cuff injury is accurate for purposes of treatment planning. SUBJECTS AND METHODS. Preoperative sonography of the rotator cuff was performed on 225 patients, and findings were classified into intact, partial tear, small full-thickness tear, large full-thickness tear, and massive tear groups. Surgical correlation with the predicted sonographic classification was provided by arthroscopic inspection or open surgery. RESULTS. The sonographic findings were surgically confirmed for 206 (92%) of the 225 patients. More extensive cuff injury was encountered during surgery than had been predicted sonographically in 11 patients (5%); less extensive injury than predicted was found during surgery in eight patients (4%). CONCLUSION. Our results show a high correlation between the sonographic classification of rotator cuff injury and the surgical findings. The selection of appropriate treatment programs can be reliably based on the sonographic classification.
Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
Am. J. Roentgenol.Home page
J. O. de Jesus, L. Parker, A. J. Frangos, and L. N. Nazarian
Accuracy of MRI, MR Arthrography, and Ultrasound in the Diagnosis of Rotator Cuff Tears: A Meta-Analysis
Am. J. Roentgenol., June 1, 2009; 192(6): 1701 - 1707.
[Abstract] [Full Text] [PDF]


Home page
Ann Rheum DisHome page
G A W Bruyn, E Naredo, I Moller, C Moragues, J Garrido, G H de Bock, M-A d'Agostino, E Filippucci, A Iagnocco, M Backhaus, et al.
Reliability of ultrasonography in detecting shoulder disease in patients with rheumatoid arthritis
Ann Rheum Dis, March 1, 2009; 68(3): 357 - 361.
[Abstract] [Full Text] [PDF]


Home page
J Bone Joint Surg BrHome page
S. Moosmayer, H.-J. Smith, R. Tariq, and A. Larmo
Prevalence and characteristics of asymptomatic tears of the rotator cuff: AN ULTRASONOGRAPHIC AND CLINICAL STUDY
J Bone Joint Surg Br, February 1, 2009; 91-B(2): 196 - 200.
[Abstract] [Full Text] [PDF]


Home page
J Bone Joint Surg BrHome page
A. Al-Shawi, R. Badge, and T. Bunker
The detection of full thickness rotator cuff tears using ultrasound
J Bone Joint Surg Br, July 1, 2008; 90-B(7): 889 - 892.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
V. Khoury, E. Cardinal, and P. Brassard
Atrophy and Fatty Infiltration of the Supraspinatus Muscle: Sonography Versus MRI
Am. J. Roentgenol., April 1, 2008; 190(4): 1105 - 1111.
[Abstract] [Full Text] [PDF]


Home page
J Am Acad Orthop SurgHome page
A. B. Wolff, P. Sethi, K. M. Sutton, A. S. Covey, D. P. Magit, and M. Medvecky
Partial-Thickness Rotator Cuff Tears
J. Am. Acad. Ortho. Surg., December 1, 2006; 14(13): 715 - 725.
[Abstract] [Full Text] [PDF]


Home page
RadioGraphicsHome page
M. J. C. M. Rutten, G. J. Jager, and J. G. Blickman
From the RSNA Refresher Courses: US of the Rotator Cuff: Pitfalls, Limitations, and Artifacts.
RadioGraphics, March 1, 2006; 26(2): 589 - 604.
[Abstract] [Full Text] [PDF]


Home page
Am J Sports MedHome page
S. Fealy, R. S. Adler, M. C. Drakos, A. M. Kelly, A. A. Allen, F. A. Cordasco, R. F. Warren, and S. J. O'Brien
Patterns of Vascular and Anatomical Response After Rotator Cuff Repair
Am. J. Sports Med., January 1, 2006; 34(1): 120 - 127.
[Abstract] [Full Text] [PDF]


Home page
radtechHome page
J. MINIGH
Imaging Sports-related Injuries
Radiol. Technol., November 1, 2005; 77(2): 121 - 138.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
K. Strobel, J. Hodler, D. C. Meyer, C. W. A. Pfirrmann, C. Pirkl, and M. Zanetti
Fatty Atrophy of Supraspinatus and Infraspinatus Muscles: Accuracy of US
Radiology, November 1, 2005; 237(2): 584 - 589.
[Abstract] [Full Text] [PDF]


Home page
Am J Sports MedHome page
M. J. Matava, D. B. Purcell, and J. R. Rudzki
Partial-Thickness Rotator Cuff Tears
Am. J. Sports Med., September 1, 2005; 33(9): 1405 - 1417.
[Abstract] [Full Text] [PDF]


Home page
J Bone Joint Surg BrHome page
C. Charousset, L. Bellaiche, L. D. Duranthon, and J. Grimberg
Accuracy of CT arthrography in the assessment of tears of the rotator cuff
J Bone Joint Surg Br, June 1, 2005; 87-B(6): 824 - 828.
[Abstract] [Full Text] [PDF]


Home page
JBJSHome page
J. P. Iannotti, J. Ciccone, D. D. Buss, J. L. Visotsky, E. Mascha, K. Cotman, and N. M. Rawool
Accuracy of Office-Based Ultrasonography of the Shoulder for the Diagnosis of Rotator Cuff Tears
J. Bone Joint Surg. Am., June 1, 2005; 87(6): 1305 - 1311.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
S. A. Teefey, W. D. Middleton, W. T. Payne, and K. Yamaguchi
Detection and Measurement of Rotator Cuff Tears with Sonography: Analysis of Diagnostic Errors
Am. J. Roentgenol., June 1, 2005; 184(6): 1768 - 1773.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
M. Ferri, K. Finlay, T. Popowich, G. Stamp, P. Schuringa, and L. Friedman
Sonography of Full-Thickness Supraspinatus Tears: Comparison of Patient Positioning Technique with Surgical Correlation
Am. J. Roentgenol., January 1, 2005; 184(1): 180 - 184.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
W. D. Middleton, S. A. Teefey, and K. Yamaguchi
Sonography of the Rotator Cuff: Analysis of Interobserver Variability
Am. J. Roentgenol., November 1, 2004; 183(5): 1465 - 1468.
[Abstract] [Full Text] [PDF]


Home page
JBJSHome page
S. A. Teefey, D. A. Rubin, W. D. Middleton, C. F. Hildebolt, R. A. Leibold, and K. Yamaguchi
Detection and Quantification of Rotator Cuff Tears. Comparison of Ultrasonographic, Magnetic Resonance Imaging, and Arthroscopic Findings in Seventy-one Consecutive Cases
J. Bone Joint Surg. Am., April 1, 2004; 86(4): 708 - 716.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
J. A. Jacobson, S. Lancaster, A. Prasad, M. T. van Holsbeeck, J. G. Craig, and P. Kolowich
Full-Thickness and Partial-Thickness Supraspinatus Tendon Tears: Value of US Signs in Diagnosis
Radiology, January 1, 2004; 230(1): 234 - 242.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
K. Strobel, M. Zanetti, L. Nagy, and J. Hodler
Suspected Rotator Cuff Lesions: Tissue Harmonic Imaging versus Conventional US of the Shoulder
Radiology, January 1, 2004; 230(1): 243 - 249.
[Abstract] [Full Text] [PDF]


Home page
J Ultrasound MedHome page
AIUM Practice Guideline for the Performance of a Shoulder Ultrasound Examination
J. Ultrasound Med., October 1, 2003; 22(10): 1137 - 1141.
[Full Text] [PDF]


Home page
J Ultrasound MedHome page
H. P. Wu, T. J. Dubinsky, and M. L. Richardson
Association of Shoulder Sonographic Findings With Subsequent Surgical Treatment for Rotator Cuff Injury
J. Ultrasound Med., February 1, 2003; 22(2): 155 - 161.
[Abstract] [Full Text] [PDF]


Home page
Journal of Diagnostic Medical SonographyHome page
D. P. Bahner, J. A. Bradley, and D. A. Rund
Acute Frontal Sinus Fracture: An Innovative Use of Sonography
Journal of Diagnostic Medical Sonography, September 1, 2002; 18(5): 325 - 327.
[Abstract] [PDF]


Home page
ImagingHome page
J R C Ellis, J L Teh, and P M Scott
Ultrasound of tendons
Imaging, June 1, 2002; 14(3): 223 - 228.
[Abstract] [Full Text] [PDF]


Home page
Ann Rheum DisHome page
E Naredo, P Aguado, E De Miguel, J Uson, L Mayordomo, J Gijon-Banos, and E Martin-Mola
Painful shoulder: comparison of physical examination and ultrasonographic findings
Ann Rheum Dis, February 1, 2002; 61(2): 132 - 136.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
J. Lin, J. A. Jacobson, D. P. Fessell, W. J. Weadock, and C. W. Hayes
An Illustrated Tutorial of Musculoskeletal Sonography: Part 2, Upper Extremity
Am. J. Roentgenol., October 1, 2000; 175(4): 1071 - 1079.
[Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
M. S. Taljanovic, K. L. Carlson, J. E. Kuhn, J. A. Jacobson, L. O. Delaney-Sathy, and R. S. Adler
Sonography of the Glenoid Labrum: A Cadaveric Study with Arthroscopic Correlation
Am. J. Roentgenol., June 1, 2000; 174(6): 1717 - 1722.
[Abstract] [Full Text]


Home page
RadioGraphicsHome page
C. J. Seibold, T. A. Mallisee, S. J. Erickson, M. D. Boynton, W. G. Raasch, and M. E. Timins
Rotator Cuff: Evaluation with US and MR Imaging
RadioGraphics, May 1, 1999; 19(3): 685 - 705.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1993 by the American Roentgen Ray Society.