AJR F and L Medical Products: Radiation Protection & More
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Behan, M.
Right arrow Articles by Carney, D. N.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Behan, M.
Right arrow Articles by Carney, D. N.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
Hotlight (NEW!)
Right arrow
What's Hotlight?

American Journal of Roentgenology, Vol 160, 399-405, Copyright © 1993 by American Roentgen Ray Society


ARTICLES

Perfluorooctylbromide as a contrast agent for CT and sonography: preliminary clinical results

M Behan, D O'Connell, RF Mattrey and DN Carney
Department of Radiology, Mater Misericordiae Hospital, Dublin, Ireland.

OBJECTIVE. Perflubron emulsion is a bromine-based particulate contrast agent that is taken up selectively by the liver and spleen after IV injection. It does not leave the vascular space and also persists in the blood for a longer period than iodinated contrast agents do. We performed a preliminary study to determine the value of the IV perflubron emulsion as a contrast material for CT and sonography. SUBJECTS AND METHODS. To determine the safety and dose response of perflubron emulsion as an IV contrast agent for CT and sonography, 18 cancer patients, 14 of whom had hepatic metastases, were given 0.5-3.0 ml/kg of the emulsion. Sonography and CT of the liver and spleen were performed before and immediately after infusion and then again at 24 hr. RESULTS. A persistent increase in the density of blood, liver, and spleen was observed, where maximal enhancements of 55, 39, and 317 H, respectively, were achieved. Tumor conspicuity increased as metastases enhanced minimally (7 H or less). Peak enhancement of the liver and spleen was delayed to 24 hr with higher doses of perflubron; however, the immediate postinfusion scan allowed the distinction of vessels from hepatic lesions. Sonographically, an increase in tumor echogenicity relative to liver was observed in nine of the 14 subjects, allowing the detection of additional metastases in two. Splenic echogenicity in the near field increased relative to kidney; however, attenuation increased markedly at the time of peak concentration, limiting beam penetration. Similar but milder changes were observed in the liver. Adverse effects occurred in 14 of the subjects; these included lower back pain in six, delayed fever in eight, and malaise in three. CONCLUSION. Perflubron emulsion produced prolonged enhancement of blood, liver, and spleen and increased the conspicuity of liver metastases. However, the side effects encountered could limit its use to a selected population of patients.
Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
RadiologyHome page
F. Forsberg, B. B. Goldberg, J.-B. Liu, D. A. Merton, N. M. Rawool, and W. T. Shi
Tissue-Specific US Contrast Agent for Evaluation of Hepatic and Splenic Parenchyma
Radiology, January 1, 1999; 210(1): 125 - 132.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS