American Journal of Roentgenology, Vol 160, 473-477, Copyright © 1993 by American Roentgen Ray Society
ARTICLES |
MS Frank, RG Jost, PL Molina, DJ Anderson, SL Solomon, RA Whitman and SM Moore
Harborview Medical Center, University of Washington, Department of Radiology, Seattle 98104.
OBJECTIVE. The suitability of using a high-resolution computer-display system for primary interpretation of adult chest radiographs obtained with portable apparatus and storage phosphor technology was evaluated with receiver operating characteristic analysis and subjective methods. MATERIALS AND METHODS. Sixty portable digital chest radiographs showing abnormalities that approached the resolution limits of our computed radiography system were selected. The original digital data making up the 2140 x 1760 x 10 bit images were transferred to a cathode ray tube (CRT) display system composed of two Megascan monitors. Postprocessing rendered two images, one for each monitor, to emulate the two-on-one hard-copy format produced by the computed radiography system. Each image set was interpreted independently by three radiologists experienced with hard-copy format. Limited level and window adjustments were allowed during CRT interpretation. For both CRT and hard-copy display, images were graded on the basis of the interpreter's confidence in the presence of pneumothorax and parenchymal abnormalities. Three types of foreign devices were subjectively analyzed: endotracheal tubes, nasogastric tubes, and temporary epicardial pacer wires. RESULTS. No significant differences were found in detecting pneumothorax or focal infiltrates. One radiologist found the hard copy better for detecting diffuse infiltrates (p = .02); two radiologists favored CRT for visualizing nasogastric tubes (p < .005, p < .02); and one radiologist favored CRT for visualizing temporary epicardial pacer wires (p = .05). CONCLUSION. We conclude that an optimized high-resolution CRT system is quite promising for primary interpretation of digital portable chest radiographs, but further investigation and greater statistical power are necessary to confirm our results.
This article has been cited by other articles:
![]() |
J. M. Goo, J.-G. Im, H. J. Lee, M. J. Chung, J. B. Seo, H. Y. Kim, Y.-J. Lee, J.-W. Kang, and J. H. Kim Detection of Simulated Chest Lesions by Using Soft-Copy Reading: Comparison of an Amorphous Silicon Flat-Panel-Detector System and a Storage-Phosphor System Radiology, July 1, 2002; 224(1): 242 - 246. [Abstract] [Full Text] |
||||
![]() |
J. Eng, W. K. Mysko, G. E. R. Weller, R. Renard, J. N. Gitlin, D. A. Bluemke, D. Magid, G. D. Kelen, and W. W. Scott Jr. Interpretation of Emergency Department Radiographs: A Comparison of Emergency Medicine Physicians with Radiologists, Residents with Faculty, and Film with Digital Display Am. J. Roentgenol., November 1, 2000; 175(5): 1233 - 1238. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. M. Goo, J.-G. Im, J. H. Kim, J. B. Seo, T. S. Kim, S. J. Shine, and W. Lee Digital Chest Radiography with a Selenium-Based Flat-Panel Detector Versus a Storage Phosphor System: Comparison of Soft-Copy Images Am. J. Roentgenol., October 1, 2000; 175(4): 1013 - 1018. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |