AJR F and L Medical Products: Radiation Protection & More
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Mayo, J. R.
Right arrow Articles by Muller, N. L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Mayo, J. R.
Right arrow Articles by Muller, N. L.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
Hotlight (NEW!)
Right arrow
What's Hotlight?

American Journal of Roentgenology, Vol 160, 479-481, Copyright © 1993 by American Roentgen Ray Society


ARTICLES

High-resolution CT of the chest: radiation dose

JR Mayo, SA Jackson and NL Muller
Department of Radiology, University of British Columbia, Vancouver, Canada.

OBJECTIVE. The purpose of this study was to compare the skin radiation dose to the chest produced by high-resolution CT (HRCT) with the radiation dose produced by conventional CT. Previous studies have reported that radiation doses with HRCT are equal to or higher than those with conventional CT. These results, however, were based on the assumption that in HRCT, contiguous sections were scanned without the intersection gaps of 10 or 20 mm that are used clinically. SUBJECTS AND METHODS. We used radiotherapy verification film to measure the skin radiation dose in 56 patients who had chest CT scans. Twenty-two had 1.5-mm collimation HRCT scans at 10-mm intervals, 15 had 1.5-mm collimation HRCT scans at 20-mm intervals, and 19 had 10-mm collimation conventional CT scans at 10-mm intervals. Scan parameters were identical in all cases: 120 kVp, 200 mA, 2 sec. Step wedges were used to generate calibration films with identical beam quality on the CT scanner, and exposure was measured with an ionization chamber. Calibration films and patients' radiotherapy verification films were digitized, and the radiation dose was calculated. RESULTS. Mean skin radiation dose was 4.4 (standard error [SE], 0.2) mGy for 1.5-mm HRCT scans at 10-mm intervals, 2.1 (SE, 0.1) mGy at 20-mm intervals, and 36.3 (SE, 0.9) mGy for conventional 10-mm scans at 10-mm intervals. CONCLUSION. HRCT scanning at 10- and 20-mm intervals produced 12% and 6%, respectively, of the radiation dose associated with conventional CT. This is considerably less radiation than suggested in earlier studies. Combining HRCT scans at 20-mm intervals with low-dose scan (20 mA, 2-sec scans) would result in an average skin dose comparable with the dose administered with chest radiography.
Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
Proc Am Thorac SocHome page
F. R. Long
High-Resolution Computed Tomography of the Lung in Children with Cystic Fibrosis: Technical Factors
Proceedings of the ATS, August 1, 2007; 4(4): 306 - 309.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
A. S. Brody, H. A. W. M. Tiddens, R. G. Castile, H. O. Coxson, P. A. de Jong, J. Goldin, W. Huda, F. R. Long, M. McNitt-Gray, M. Rock, et al.
Computed Tomography in the Evaluation of Cystic Fibrosis Lung Disease
Am. J. Respir. Crit. Care Med., November 15, 2005; 172(10): 1246 - 1252.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
D. A. Leswick, S. T. Webster, B. A. Wilcox, and D. A. Fladeland
Radiation Cost of Helical High-Resolution Chest CT
Am. J. Roentgenol., March 1, 2005; 184(3): 742 - 745.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
M. Remy-Jardin, A. Sobaszek, A. Duhamel, I. Mastora, C. Zanetti, and J. Remy
Asbestos-related Pleuropulmonary Diseases: Evaluation with Low-Dose Four-Detector Row Spiral CT
Radiology, October 1, 2004; 233(1): 182 - 190.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
I. Mastora, M. Remy-Jardin, V. Delannoy, A. Duhamel, C. Scherf, C. Suess, and J. Remy
Multi-Detector Row Spiral CT Angiography of the Thoracic Outlet: Dose Reduction with Anatomically Adapted Online Tube Current Modulation and Preset Dose Savings
Radiology, January 1, 2004; 230(1): 116 - 124.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
J. R. Mayo, J. Aldrich, and N. L. Muller
Radiation Exposure at Chest CT: A Statement of the Fleischner Society
Radiology, July 1, 2003; 228(1): 15 - 21.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
E. L. Nickoloff and P. O. Alderson
Radiation Exposures to Patients from CT: Reality, Public Perception, and Policy
Am. J. Roentgenol., August 1, 2001; 177(2): 285 - 287.
[Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
U. J. Schoepf, R. D. Bruening, C. Hong, R. Eibel, S. Aydemir, A. Crispin, C. Becker, and M. F. Reiser
Multislice Helical CT of Focal and Diffuse Lung Disease: Comprehensive Diagnosis with Reconstruction of Contiguous and High-Resolution CT Sections from a Single Thin-Collimation Scan
Am. J. Roentgenol., July 1, 2001; 177(1): 179 - 184.
[Abstract] [Full Text] [PDF]


Home page
Eur Respir JHome page
H. De Raeve, J.A. Verschakelen, P.A. Gevenois, P. Mahieu, G. Moens, and B. Nemery
Observer variation in computed tomography of pleural lesions in subjects exposed to indoor asbestos
Eur. Respir. J., May 1, 2001; 17(5): 916 - 921.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
J. Lucaya, J. Piqueras, P. Garcia-Pena, G. Enriquez, M. Garcia-Macias, and J. Sotil
Low-Dose High-Resolution CT of the Chest in Children and Young Adults: Dose, Cooperation, Artifact Incidence, and Image Quality
Am. J. Roentgenol., October 1, 2000; 175(4): 985 - 992.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
K. E. Thomas, C. M. Owens, J. Britto, S. Nadel, P. Habibi, and R. Nicholson
Efficacy of Chest CT in a Pediatric ICU : A Prospective Study
Chest, June 1, 2000; 117(6): 1697 - 1705.
[Abstract] [Full Text] [PDF]


Home page
ThoraxHome page
D. M Mitchell and A. Woodcock
Introduction
Thorax, August 1, 1999; 54(90002): S1 - 1.
[PDF]


Home page
ThoraxHome page
A. Wells
Clinical usefulness of high resolution computed tomography in cryptogenic fibrosing alveolitis
Thorax, December 1, 1998; 53(12): 1080 - 1087.
[Full Text]


Home page
BMJHome page
S. Worthy
High resolution computed tomography of the lungs
BMJ, March 11, 1995; 310(6980): 616 - 616.
[Full Text]


Home page
ThoraxHome page
B. T. SOCIETY and S. O. C. COMMITTEE
The Diagnosis, Assessment and Treatment of Diffuse Parenchymal Lung Disease in Adults---British Thoracic Society recommendations
Thorax, April 1, 1990; 54(90001): 1S - 28.
[Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1993 by the American Roentgen Ray Society.