AJR ARRS Membership
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Baker, M. E.
Right arrow Articles by Dunnick, N. R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Baker, M. E.
Right arrow Articles by Dunnick, N. R.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?

American Journal of Roentgenology, Vol 160, 637-641, Copyright © 1993 by American Roentgen Ray Society


ARTICLES

Contrast material for combined abdominal and pelvic CT: can cost be reduced by increasing the concentration and decreasing the volume?

ME Baker, C Beam, R Leder, D Gulliver, SS Paine and NR Dunnick
Department of Radiology, Duke University Medical Center, Durham, NC 27710.

OBJECTIVE. The purpose of this study was to determine if enhancement provided by a smaller volume of a more concentrated nonionic contrast agent is equivalent to that provided by a larger volume of a less concentrated nonionic agent on dynamic, incremental abdominal and pelvic CT. SUBJECTS AND METHODS. During a 4-month period, 168 patients undergoing dynamic incremental abdominal and pelvic CT received 150 ml iopamidol-300 (45 g iodine). During the following 4 months, 119 patients received 125 ml ioversol-320 (40 g iodine). The same automated injector and scanning parameters were used for both groups. Absolute enhancement of the liver at three levels and of abdominal and pelvic vessels was calculated and analyzed by using Student's t-test. RESULTS. Arterial and venous enhancement in the upper part of the abdomen, at the level of the iliac crest, or in the pelvis was not significantly different with the two contrast agents. Both ioversol and iopamidol provided the same mean enhancement of the hepatic parenchyma at the level of the hepatic veins (45 H) and at the level of the portal vein (49 H). At the level of the gallbladder fossa, enhancement of liver parenchyma with the two contrast agents was significantly different (p = .04): mean enhancement was 45 H for iopamidol and 42 H for ioversol. A retrospective analysis of the liver enhancement profiles from 50 randomly selected patients from each group showed no significant difference in parenchymal enhancement. CONCLUSION. For dynamic abdominal and pelvic CT, no statistically significant difference was found between the mean enhancement of the liver and abdominal vessels after administration of 125 ml of ioversol-320 and that after administration of 150 ml of iopamidol-300. Therefore, 125 ml of ioversol-320 can be used instead of 150 ml of iopamidol-300 without compromising image quality. At current prices, this will result in savings of approximately 18% per patient.
Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
Am. J. Roentgenol.Home page
F. Orlandini, S. Boini, S. Iochum-Duchamps, T. Batch, X. Zhu, and A. Blum
Assessment of the use of a saline chaser to reduce the volume of contrast medium in abdominal CT.
Am. J. Roentgenol., August 1, 2006; 187(2): 511 - 515.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
A. J. Megibow, G. Jacob, J. P. Heiken, E. K. Paulson, K. D. Hopper, G. Sica, S. Saini, B. A. Birnbaum, R. Redvanley, and E. K. Fishman
Quantitative and Qualitative Evaluation of Volume of Low Osmolality Contrast Medium Needed for Routine Helical Abdominal CT
Am. J. Roentgenol., March 1, 2001; 176(3): 583 - 589.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
B. R. Herts, C. M. O'Malley, S. L. Wirth, M. L. Lieber, and B. Pohlman
Power Injection of Contrast Media Using Central Venous Catheters: Feasibility, Safety, and Efficacy
Am. J. Roentgenol., February 1, 2001; 176(2): 447 - 453.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1993 by the American Roentgen Ray Society.