AJR Women's Imaging Online
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Burkart, D. J.
Right arrow Articles by Ehman, R. L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Burkart, D. J.
Right arrow Articles by Ehman, R. L.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?

American Journal of Roentgenology, Vol 160, 1113-1118, Copyright © 1993 by American Roentgen Ray Society


ARTICLES

Volumetric flow rates in the portal venous system: measurement with cine phase-contrast MR imaging

DJ Burkart, CD Johnson, MJ Morton, RL Wolf and RL Ehman
Department of Diagnostic Radiology, Mayo Clinic, Rochester, MN 55905.

OBJECTIVE. The purposes of this study were to (1) validate the accuracy of cine phase-contrast MR flow measurements within the portal vein, (2) develop a suitable protocol for using this method to measure volumetric flow rate in the portal venous system, and (3) use this protocol, with Doppler sonography as a reference, to measure portal venous flow in healthy volunteers and in patients with protal venous hypertension. SUBJECTS AND METHODS. Flow determinations were obtained in a model of fluid movement approximating blood-flow conditions in the portal venous system. A suitable protocol was based on consideration of the theoretical effects of (1) spatial resolution, (2) obliquity of the imaging plane to the direction of flow, and (3) signal-to-noise ratio of the signed quantitative velocity images (in three volunteers) on the accuracy and precision of flow measurements. This protocol was used to obtain cine phase-contrast MR images of the portal venous system in five volunteers and six patients. RESULTS. Values obtained with a flow phantom showed good accuracy of cine phase-contrast-measured vs actual volumetric flow rate (r = .995; p = .0001; MR rate = [0.94 x actual rate] + 65.6 ml/min; standard error of the y estimate = 67.3 ml/min). Velocity encoding and section thickness substantially influenced the signal-to-noise ratio of the velocity images, whereas flip angle and matrix size had only minimal effect. In volunteers and patients, portal volumetric flow rates determined by using MR images and Doppler sonography showed good correlation (r = .94; p = .0003). CONCLUSION. Our results indicate that cine phase-contrast MR imaging is a practical noninvasive method for measuring volumetric flow rates in the portal venous system.
Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
Am. J. Neuroradiol.Home page
N. Hirabuki, Y. Watanabe, T. Mano, N. Fujita, H. Tanaka, T. Ueguchi, and H. Nakamura
Quantitation of Flow in the Superior Sagittal Sinus Performed with Cine Phase-contrast MR Imaging of Healthy and Achondroplastic Children
AJNR Am. J. Neuroradiol., August 1, 2000; 21(8): 1497 - 1501.
[Abstract] [Full Text]