AJR Women's Imaging Online
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kimme-Smith, C.
Right arrow Articles by Bassett, L. W.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kimme-Smith, C.
Right arrow Articles by Bassett, L. W.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?

American Journal of Roentgenology, Vol 162, 1313-1317, Copyright © 1994 by American Roentgen Ray Society


ARTICLES

Mammograms obtained with rhodium vs molybdenum anodes: contrast and dose differences

C Kimme-Smith, J Wang, N DeBruhl, M Basic and LW Bassett
Iris Cantor Center for Breast Imaging, University of California, School of Medicine, Los Angeles 90024.

OBJECTIVE. A mammography unit with both a molybdenum anode and a rhodium anode, filtered with molybdenum and rhodium, respectively, was evaluated to determine which types of women would benefit from the dose savings of the rhodium combination despite some loss of contrast. SUBJECTS AND MATERIALS. In 100 women, the molybdenum anode and molybdenum filtration (Mo/Mo) were used to obtain mammograms of the right breast, and the rhodium anode and rhodium filtration (Rh/Rh) were used for mammograms of the left breast. All mammograms were obtained at 26 kVp. All milliampere-second values used to radiograph the breasts of these women were recorded. Mammograms of 54 women (30 with previous mammograms available), representing the four types of breasts as defined by the American College of Radiology, were interpreted by three radiologists. Each mammogram was assigned a grade for breast type, preference (Rh/Rh, Mo/Mo, or previous mammograms), contrast, and sharpness. RESULTS. Overall, mammograms obtained by using the Mo/Mo combination were preferred. However, for images of types 3 and 4 breasts, Rh/Rh was preferred twice as often as it had been for mammograms of types 1 and 2 breasts. The mean glandular dose for all breast types when the Rh/Rh combination was used was 42% of the dose used for the Mo/Mo combination. For a 6-cm-thick dense breast, the Rh/Rh combination required 40% of the dose required for the Mo/Mo combination. CONCLUSION. Mammograms obtained with the Rh/Rh combination carried an overall decrease in contrast and mean glandular dose. However, for young women and some women with large dense breasts, the Rh/Rh mammograms were equivalent to or better than the mammograms obtained with the Mo/Mo combination. Effective use of Rh/Rh units requires careful selection of women based on age or the amount of glandular tissue seen on previous mammograms.