AJR ARRS Membership
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Yucel, E. K.
Right arrow Articles by Carter, A. P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Yucel, E. K.
Right arrow Articles by Carter, A. P.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?

American Journal of Roentgenology, Vol 163, 197-201, Copyright © 1994 by American Roentgen Ray Society


ARTICLES

MR angiography of normal pelvic arteries: comparison of signal intensity and contrast-to-noise ratio for three different inflow techniques

EK Yucel, MS Silver and AP Carter
Department of Radiology, Boston University School of Medicine, MA 02118.

OBJECTIVE. Two-dimensional (2D) time-of-flight (TOF) MR angiography has been the standard technique for evaluating arteries of the lower extremity. However, this technique is limited by artifacts resulting from vessel pulsation, as well as by relatively poor vessel-to- background contrast. The purpose of this study was to evaluate two cardiac-gated inflow techniques to determine whether they exhibited better contrast and signal performance than the standard technique of 2D TOF MR angiography of the iliac arteries. SUBJECTS AND METHODS. Fourteen subjects who had no clinical evidence of vascular disease had standard 2D TOF, gated 2D TOF, and gated 2D turbo field-echo MR angiography. Images were evaluated for signal-intensity ratio, signal- to-noise ratio, and contrast-to-noise ratio, in addition to qualitative evaluation. RESULTS. Turbo field-echo MR angiography exhibited significantly higher signal-intensity, signal-to-noise, and contrast-to- noise ratios than did either gated or standard MR angiography for all vessel segments. We found no significant difference between gated and standard 2D TOF techniques for any vessel segment. Qualitative features of turbo field-echo MR angiography included improved visualization of horizontal vessel segments compared with the standard 2D TOF technique, less effective venous saturation compared with either the gated or standard 2D TOF technique, and increased ghosting artifacts compared with the gated 2D TOF technique. CONCLUSION. Two-dimensional turbo field-echo MR angiography exhibits improved signal and contrast for evaluation of normal iliac segments compared with standard or gated 2D TOF MR angiography. This technique should replace standard 2D TOF MR angiography for evaluation of the iliac arteries.
Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
RadiologyHome page
T. Kuehne, M. Saeed, P. Moore, K. Gleason, G. Reddy, D. Teitel, and C. B. Higgins
Influence of Blood-Pool Contrast Media on MR Imaging and Flow Measurements in the Presence of Pulmonary Arterial Stents in Swine
Radiology, May 1, 2002; 223(2): 439 - 445.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1994 by the American Roentgen Ray Society.