AJR Your Link to CME
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Monticciolo, D. L.
Right arrow Articles by Hester, T. R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Monticciolo, D. L.
Right arrow Articles by Hester, T. R.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?

American Journal of Roentgenology, Vol 163, 51-56, Copyright © 1994 by American Roentgen Ray Society


ARTICLES

MR detection of leakage from silicone breast implants: value of a silicone-selective pulse sequence

DL Monticciolo, RC Nelson, WT Dixon, J Bostwick 3rd, S Mukundan and TR Hester
Department of Radiology, Emory University School of Medicine, Atlanta, GA 30322.

OBJECTIVE. The purpose of this study was to determine the value of MR imaging with a silicone-selective pulse sequence for detecting leakage from silicone breast implants. SUBJECTS AND METHODS. Women with silicone breast implants were referred for this study on the basis of clinical or imaging findings suggestive of implant rupture. Twenty- eight patients with 38 implants were examined with silicone-selective MR imaging and also underwent surgical removal of the studied implant. All but four also had mammography before MR imaging. Results of silicone-selective MR imaging for the detection of silicone leakage were compared with mammographic and surgical findings. Surgical proof was considered the gold standard. RESULTS. Silicone-selective MR imaging showed an apparently intact implant in 21 cases; 20 of these were found to be intact at surgery. Silicone-selective MR imaging showed evidence of leakage in 17 implants, all of which showed leakage at surgery. The sensitivity for detection of leakage was 94%; the specificity was 100%. The findings of silicone-selective MR imaging and mammography were in agreement in 30 of 34 cases in which both studies were performed. In the four cases of disagreement, surgical findings agreed with MR findings in three and with mammographic findings in one. When the findings of mammography and silicone-selective MR imaging were combined, the correct status (leakage or no leakage) of all implants examined was determinable. CONCLUSION. Silicone-selective MR imaging is highly effective for detecting leakage from silicone breast implants. Accuracy is improved when mammographic and MR findings are considered together.
Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
Am. J. Roentgenol.Home page
W. A. Berg, T. K. Nguyen, M. S. Middleton, M. S. Soo, G. Pennello, and S. L. Brown
MR Imaging of Extracapsular Silicone from Breast Implants: Diagnostic Pitfalls
Am. J. Roentgenol., February 1, 2002; 178(2): 465 - 472.
[Abstract] [Full Text] [PDF]


Home page
RadioGraphicsHome page
C. I. Caskey, W. A. Berg, U. M. Hamper, S. Sheth, B. W. Chang, and N. D. Anderson
Imaging Spectrum of Extracapsular Silicone: Correlation of US, MR Imaging, Mammographic, and Histopathologic Findings
RadioGraphics, October 1, 1999; 19(90001): 39 - 51.
[Abstract] [Full Text]