American Journal of Roentgenology, Vol 163, 87-92, Copyright © 1994 by American Roentgen Ray Society
ARTICLES |
WC Small, RC Nelson, ME Bernardino and LT Brummer
Department of Radiology, Emory University School of Medicine, Atlanta, GA 30322.
OBJECTIVE. Spiral CT allows rapid hepatic imaging during a single breath-hold. The increase in imaging speed potentially allows contrast material to be used more efficaciously than with conventional dynamic CT, perhaps allowing a decrease in the volume of required contrast agent. To determine how this can be accomplished, we studied the effect of different bolus IV injection rates and amounts of contrast material on early hepatic enhancement during dynamic bolus spiral CT. SUBJECTS AND METHODS. A group of 20 healthy male volunteers were divided into four groups of five each. The groups received 75, 100, 125, or 150 ml of contrast material (Omnipaque 300, 300 mg l/ml). Each person within each group was scanned as contrast material was injected at rates of 3, 4, and 5 ml/sec. Hepatic enhancement was evaluated by comparing quantitative regions of interest before and after bolus injection of contrast material. Variations in enhancement produced by changes in volume and injection rate of contrast material were evaluated on early, middle, and late sections of the spiral, corresponding to 32-34, 41-43, and 51-53 sec, respectively, after the injection of contrast material was begun. RESULTS. Hepatic enhancement increased more rapidly when the bolus of contrast material was given at a rate of 5 ml/sec than at the slower rates of 3 or 4 ml/sec. Enhancement of the liver was greatest at the late portion of the spiral (51-53 sec after start of the bolus injection), averaging 73 and 79 H for volumes of 125 and 150 ml, respectively, at 5 ml/sec, and the enhancement was still increasing at that time. Enhancement curves predict 50- and 70-H mean increases in hepatic attenuation on initial slices with scan delays of approximately 40 and 50 sec, respectively, for these two protocols. CONCLUSION. Our results demonstrate that there is a marked dependence on early hepatic enhancement produced by variations in volume and injection rate of contrast material. We found no difference in the results produced by 125- and 150-ml volumes. These results are important for maximizing the effectiveness of IV contrast material during rapid hepatic spiral CT scanning.
This article has been cited by other articles:
![]() |
K. T. Bae, B. A. Seeck, C. F. Hildebolt, C. Tao, F. Zhu, M. Kanematsu, and P. K. Woodard Contrast Enhancement in Cardiovascular MDCT: Effect of Body Weight, Height, Body Surface Area, Body Mass Index, and Obesity Am. J. Roentgenol., March 1, 2008; 190(3): 777 - 784. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. T. Bae, C. Tao, S. Gurel, C. Hong, F. Zhu, T. A. Gebke, M. Milite, and C. F. Hildebolt Effect of Patient Weight and Scanning Duration on Contrast Enhancement during Pulmonary Multidetector CT Angiography Radiology, February 1, 2007; 242(2): 582 - 589. [Abstract] [Full Text] [PDF] |
||||
![]() |
M.-J. Kim, Y. E. Chung, K. W. Kim, J.-J. Chung, J. S. Lim, Y. T. Oh, and J. H. Kim Variation of the Time to Aortic Enhancement of Fixed-Duration Versus Fixed-Rate Injection Protocols Am. J. Roentgenol., January 1, 2006; 186(1): 185 - 192. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. J. Dorio, F. T. Lee Jr., K. P. Henseler, M. Pilot, M. A. Pozniak, T. C. Winter III, and S. A. Shock Using a Saline Chaser to Decrease Contrast Media in Abdominal CT Am. J. Roentgenol., April 1, 2003; 180(4): 929 - 934. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. J. Megibow, G. Jacob, J. P. Heiken, E. K. Paulson, K. D. Hopper, G. Sica, S. Saini, B. A. Birnbaum, R. Redvanley, and E. K. Fishman Quantitative and Qualitative Evaluation of Volume of Low Osmolality Contrast Medium Needed for Routine Helical Abdominal CT Am. J. Roentgenol., March 1, 2001; 176(3): 583 - 589. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. L. Hänninen, T. J. Vogl, R. Felfe, W. Pegios, J. Balzer, W. Clauss, and R. Felix Detection of Focal Liver Lesions at Biphasic Spiral CT: Randomized Double-Blind Study of the Effect of Iodine Concentration in Contrast Materials Radiology, August 1, 2000; 216(2): 403 - 409. [Abstract] [Full Text] |
||||
![]() |
P. I. Haigh, R. J. Brenner, and A. E. Giuliano Origin of Metallic Particles Resembling Microcalcifications on Mammograms after Use of Abrasive Cautery-Tip Cleaning Pads during Breast Surgery: Experimental Demonstration Radiology, August 1, 2000; 216(2): 539 - 544. [Abstract] [Full Text] |
||||
![]() |
B. S. Kuszyk, D. A. Bluemke, M. A. Choti, K. M. Horton, C. A. Magee, and E. K. Fishman Contrast-Enhanced CT of Small Hypovascular Hepatic Tumors: Effect of Lesion Enhancement on Conspicuity in Rabbits Am. J. Roentgenol., February 1, 2000; 174(2): 471 - 0. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. E. Tublin, F. N. Tessler, S. L. Cheng, T. L. Peters, and P. C. McGovern Effect of Injection Rate of Contrast Medium on Pancreatic and Hepatic Helical CT Radiology, January 1, 1999; 210(1): 97 - 101. [Abstract] [Full Text] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |