American Journal of Roentgenology, Vol 163, 291-295, Copyright © 1994 by American Roentgen Ray Society
ARTICLES |
ML Skolnick
Department of Radiology, University of Pittsburgh Medical Center, PA 15213.
Placement of large-bore central venous catheters via a jugular or subclavian vein is becoming increasingly common. Although the great majority of these catheters are successfully placed by clinicians using anatomic landmark techniques, this procedure is neither innocuous nor always successful. Serious complications, including hematomas, arterial injury, and pneumothorax can occur. The patient may experience considerable discomfort when multiple needle passes are made. Sonographic imaging of the jugular and subclavian veins can significantly improve the safety, speed, and comfort of the procedure by defining the vascular anatomy of the jugular and subclavian veins before puncture, showing complications from prior attempts or placements of central venous catheters in these vessels, and providing guidance for needle puncture of the jugular and subclavian veins.
This article has been cited by other articles:
![]() |
W. R. Fry, G. C. Clagett, and P. T. O'Rourke Ultrasound-Guided Central Venous Access Arch Surg, July 1, 1999; 134(7): 738 - 741. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. L. Nouwen, J. J. Wielenga, H. van Overhagen, J. S. Lameris, J. A.J.W. Kluytmans, M. D. Behrendt, W. C.J. Hop, H. A. Verbrugh, and S. de Marie Hickman Catheter-Related Infections in Neutropenic Patients: Insertion in the Operating Theater Versus Insertion in the Radiology Suite J. Clin. Oncol., April 1, 1999; 17(4): 1304 - 1304. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |