AJR F and L Medical Products: Radiation Protection & More
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by De Marco, J. K.
Right arrow Articles by Richardson, D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by De Marco, J. K.
Right arrow Articles by Richardson, D.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
Hotlight (NEW!)
Right arrow
What's Hotlight?

American Journal of Roentgenology, Vol 163, 1205-1212, Copyright © 1994 by American Roentgen Ray Society


ARTICLES

Prospective evaluation of extracranial carotid stenosis: MR angiography with maximum-intensity projections and multiplanar reformation compared with conventional angiography

JK De Marco, GM Nesbit, GE Wesbey and D Richardson
Department of Radiology, Robert Wood Johnson Hospital, University of Medicine and Dentistry of New Jersey, New Brunswick.

OBJECTIVE. The purpose of this prospective study was to compare MR angiography of the carotid artery from the aortic arch through the circle of Willis using maximum-intensity projection (MIP) and multiplanar reformation (MPR) images with intraarterial angiography in the depiction of extracranial carotid atherosclerosis. SUBJECTS AND METHODS. The carotid arteries in 20 patients were studied with MR and intraarterial angiography. MR angiography included two-dimensional (2D) time-of-flight (TOF) sequences from the aortic arch through the skull base and three-dimensional (3D) TOF sequences centered at the carotid bifurcation and multiple overlapping thin slab acquisition (MOTSA) from the skull base to above the circle of Willis. Targeted MIP images of the 2D and 3D TOF MR angiograms through each carotid bifurcation were obtained. Last, MPR images of the 3D TOF MR angiograms at the obliquity that showed the greatest stenosis were obtained. All studies were reviewed in a double-blinded fashion by two neuroradiologists. Caliper measurements of MR angiograms and intraarterial angiograms were made by using North American Symptomatic Carotid Endarterectomy Trial criteria. Global MIPs of the aortic arch and common carotid arteries from the 2D TOF MR angiograms and targeted MIPs of the intracranial carotid arteries from the MOTSA MR angiograms were compared with the intraarterial angiogram and graded as normal, mild, moderate, severely stenotic, or occluded. RESULTS. MPR of the 3D TOF MR angiograms was highly correlated with intraarterial angiograms for both observers 1 and 2 (0.94/p < .001, 0.96/p < .001 [Pearson correlation/p value]). No statistically significant difference between 3D TOF MPR and intraarterial angiography was seen with a paired t-test. With an alpha = 0.05 (5% probability of type 1 error), the power to detect a difference as small as +/- 5% stenosis between 3D TOF MPR and intraarterial angiogram was 80% for observer 1 and 90% for observer 2. Although both MIPs of the 2D and 3D TOF MR angiograms showed high Pearson correlation coefficients (0.83, 0.90) with intraarterial angiography, the paired t-test revealed a statistically significant difference in the estimation of carotid stenosis. Both observers thought the global MIPs of the 2D TOF MR angiogram allowed good to excellent visualization of the common carotid arteries. The aortic arch was seen in 70% of patients; most of the missed cases occurred early in our experience, when the 2D axial images were not placed sufficiently inferior to include the arch. No stenosis of the great vessel origins was seen in this study. All four stenoses of the intracranial internal carotid artery identified with intraarterial angiography were seen with the MOTSA MR angiogram but with a tendency to overestimate stenosis. Only one carotid siphon was thought to show severe stenosis on the MR angiogram. Intraarterial angiography showed a 50% stenosis. CONCLUSION. It is possible to image the entire carotid artery from the aortic arch through the circle of Willis with MR angiography in a clinically acceptable time. MPR of the 3D TOF MR angiogram reliably shows the percentage of carotid stenosis with no statistically significant difference compared with intraarterial angiography. The role of MR angiography in showing lesions in the circle of Willis or the aortic arch is promising, but the limited number of tandem lesions in this study makes it difficult to draw any conclusions.
Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
RadiologyHome page
D. R. Hadizadeh, J. Gieseke, S. H. Lohmaier, K. Wilhelm, J. Boschewitz, F. Verrel, H. H. Schild, and W. A. Willinek
Peripheral MR Angiography with Blood Pool Contrast Agent: Prospective Intraindividual Comparative Study of High-Spatial-Resolution Steady-State MR Angiography versus Standard-Resolution First-Pass MR Angiography and DSA
Radiology, November 1, 2008; 249(2): 701 - 711.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
F. Runck, R.P. Steiner, W.A. Bautz, and M.M. Lell
MR Imaging: Influence of Imaging Technique and Postprocessing on Measurement of Internal Carotid Artery Stenosis
AJNR Am. J. Neuroradiol., October 1, 2008; 29(9): 1736 - 1742.
[Abstract] [Full Text] [PDF]


Home page
StrokeHome page
S. M. Debrey, H. Yu, J. K. Lynch, K.-O. Lovblad, V. L. Wright, S.-J. D. Janket, and A. E. Baird
Diagnostic Accuracy of Magnetic Resonance Angiography for Internal Carotid Artery Disease: A Systematic Review and Meta-Analysis
Stroke, August 1, 2008; 39(8): 2237 - 2248.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
M. Lell, C. Fellner, U. Baum, T. Hothorn, R. Steiner, W. Lang, W. Bautz, and F.A. Fellner
Evaluation of Carotid Artery Stenosis with Multisection CT and MR Imaging: Influence of Imaging Modality and Postprocessing
AJNR Am. J. Neuroradiol., January 1, 2007; 28(1): 104 - 110.
[Abstract] [Full Text] [PDF]


Home page
RadioGraphicsHome page
H. Ota, K. Takase, H. Rikimaru, M. Tsuboi, T. Yamada, A. Sato, S. Higano, T. Ishibashi, and S. Takahashi
Quantitative Vascular Measurements in Arterial Occlusive Disease
RadioGraphics, September 1, 2005; 25(5): 1141 - 1158.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
R. Raman, S. Napel, and G. D. Rubin
Curved-Slab Maximum Intensity Projection: Method and Evaluation
Radiology, October 1, 2003; 229(1): 255 - 260.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
P. J. Nederkoorn, O. E. H. Elgersma, Y. van der Graaf, B. C. Eikelboom, L. J. Kappelle, and W. P. T. M. Mali
Carotid Artery Stenosis: Accuracy of Contrast-enhanced MR Angiography for Diagnosis
Radiology, September 1, 2003; 228(3): 677 - 682.
[Abstract] [Full Text] [PDF]


Home page
StrokeHome page
P. J. Nederkoorn, Y. van der Graaf, and M.G. M. Hunink
Duplex Ultrasound and Magnetic Resonance Angiography Compared With Digital Subtraction Angiography in Carotid Artery Stenosis: A Systematic Review
Stroke, May 1, 2003; 34(5): 1324 - 1331.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
W. M. Adams, R. D. Laitt, and A. Jackson
The Role of MR Angiography in the Pretreatment Assessment of Intracranial Aneurysms: A Comparative Study
AJNR Am. J. Neuroradiol., October 1, 2000; 21(9): 1618 - 1628.
[Abstract] [Full Text]


Home page
CirculationHome page
T. S. Hatsukami, R. Ross, N. L. Polissar, and C. Yuan
Visualization of Fibrous Cap Thickness and Rupture in Human Atherosclerotic Carotid Plaque In Vivo With High-Resolution Magnetic Resonance Imaging
Circulation, August 29, 2000; 102(9): 959 - 964.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
O. E. H. Elgersma, A. F. J. Wüst, P. C. Buijs, Y. van der Graaf, B. C. Eikelboom, and W. P. T. M. Mali
Multidirectional Depiction of Internal Carotid Arterial Stenosis: Three-dimensional Time-of-Flight MR Angiography versus Rotational and Conventional Digital Subtraction Angiography
Radiology, August 1, 2000; 216(2): 511 - 516.
[Abstract] [Full Text]


Home page
CirculationHome page
E. K. Yucel, C. M. Anderson, R. R. Edelman, T. M. Grist, R. A. Baum, W. J. Manning, A. Culebras, and W. Pearce
Magnetic Resonance Angiography : Update on Applications for Extracranial Arteries
Circulation, November 30, 1999; 100(22): 2284 - 2301.
[Full Text] [PDF]


Home page
StrokeHome page
H. T. Rasanen, H. I. Manninen, R. L. Vanninen, P. Vainio, M. Berg, and T. Saari
Mild Carotid Artery Atherosclerosis : Assessment by 3-Dimensional Time-of-Flight Magnetic Resonance Angiography, With Reference to Intravascular Ultrasound Imaging and Contrast Angiography
Stroke, April 1, 1999; 30(4): 827 - 833.
[Abstract] [Full Text] [PDF]


Home page
StrokeHome page
J. Yao, M. R. H. M. van Sambeek, A. Dall'Agata, L. C. van Dijk, M. Kozakova, P. J. Koudstaal, and J. R. T. C. Roelandt
Three-Dimensional Ultrasound Study of Carotid Arteries Before and After Endarterectomy : Analysis of Stenotic Lesions and Surgical Impact on the Vessel
Stroke, October 1, 1998; 29(10): 2026 - 2031.
[Abstract] [Full Text] [PDF]


Home page
StrokeHome page
B. Young, W. S. Moore, J. T. Robertson, J. F. Toole, C. B. Ernst, S. N. Cohen, J. P. Broderick, R. J. Dempsey, and J. D. Hosking
An Analysis of Perioperative Surgical Mortality and Morbidity in the Asymptomatic Carotid Atherosclerosis Study
Stroke, December 1, 1996; 27(12): 2216 - 2224.
[Abstract] [Full Text]


Home page
StrokeHome page
M. R. Patel, K. M. Kuntz, R. A. Klufas, D. Kim, J. Kramer, J. F. Polak, J. J. Skillman, A. D. Whittemore, R. R. Edelman, and K. C. Kent
Preoperative Assessment of the Carotid Bifurcation : Can Magnetic Resonance Angiography and Duplex Ultrasonography Replace Contrast Arteriography?
Stroke, October 1, 1995; 26(10): 1753 - 1758.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1994 by the American Roentgen Ray Society.