American Journal of Roentgenology, Vol 164, 603-607, Copyright © 1995 by American Roentgen Ray Society
ARTICLES |
JR Mayo, TE Hartman, KS Lee, SL Primack, S Vedal and NL Muller
Department of Radiology, University of British Columbia, Vancouver, Canada.
OBJECTIVE. We wanted to determine minimal tube current (mAs) required for consistently good image quality on conventional 10-mm collimation chest CT and effect of tube current reduction on detection of mediastinal and lung abnormalities. Tube current reduction is desirable to reduce patient radiation dose. SUBJECTS AND METHODS. Prospectively, 30 consecutive patients (mean weight, 68 kg; range, 34-93 kg) older than 45 undergoing conventional chest CT with standard technique (120 kVp, 400 mAs) had four additional sections imaged at reduced tube current (200, 140, 80, 20 mAs) at two levels (tracheal carina and left atrium). CT scans were evaluated in random order by two independent observers who were blinded to technical factors used. Subjective image quality was graded on a five-point scale from non-diagnostic to excellent. Visualization of mediastinal adenopathy (n = 18), pleural plaques (n = 17), effusions (n = 28), lung parenchymal nodules (n = 37), and emphysema (n = 15) were assessed. The 400 mAs scan was considered the reference standard. RESULTS. When compared with the reference technique (400 mAs), the first and second (200 mAs and 140 mAs) reduction levels showed no significant difference (p > .05) in subjective image quality. A significant difference (p < .001) was seen at the third and fourth (80 mAs and 20 mAs) reduction levels. However, no significant difference (p > .05) was seen in detection of mediastinal or lung parenchymal abnormalities with different tube currents. CONCLUSION. A twofold reduction in tube current (400-140 mAs) and resultant radiation dose did not cause a significant change in subjective image quality or in detection of mediastinal or lung abnormalities with conventional chest CT. One hundred forty milliampere- seconds is the minimal tube current required to provide good image quality in patients of average weight.
This article has been cited by other articles:
![]() |
T. Kubo, P.-J. P. Lin, W. Stiller, M. Takahashi, H.-U. Kauczor, Y. Ohno, and H. Hatabu Radiation Dose Reduction in Chest CT: A Review Am. J. Roentgenol., February 1, 2008; 190(2): 335 - 343. [Abstract] [Full Text] [PDF] |
||||
![]() |
W Mazrani, K McHugh, and P J Marsden The radiation burden of radiological investigations Arch. Dis. Child., December 1, 2007; 92(12): 1127 - 1131. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. A. Bankier, C. Schaefer-Prokop, V. De Maertelaer, D. Tack, P. Jaksch, W. Klepetko, and P. A. Gevenois Air Trapping: Comparison of Standard-Dose and Simulated Low-Dose Thin-Section CT Techniques Radiology, March 1, 2007; 242(3): 898 - 906. [Abstract] [Full Text] [PDF] |
||||
![]() |
Y. Nakayama, K. Awai, Y. Funama, D. Liu, T. Nakaura, Y. Tamura, and Y. Yamashita Lower tube voltage reduces contrast material and radiation doses on 16-MDCT aortography. Am. J. Roentgenol., November 1, 2006; 187(5): W490 - W497. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. K. Yousefzadeh, M. B. Ward, and C. Reft Internal Barium Shielding to Minimize Fetal Irradiation in Spiral Chest CT: A Phantom Simulation Experiment. Radiology, June 1, 2006; 239(3): 751 - 758. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. Tack, V. De Maertelaer, W. Petit, P. Scillia, P. Muller, C. Suess, and P. A. Gevenois Multi-Detector Row CT Pulmonary Angiography: Comparison of Standard-Dose and Simulated Low-Dose Techniques Radiology, July 1, 2005; 236(1): 318 - 325. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. J. Golding Multi-slice computed tomography (MSCT): the dose challenge of the new revolution Radiat Prot Dosimetry, May 17, 2005; 114(1-3): 303 - 307. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. D. Rubin, J. K. Lyo, D. S. Paik, A. J. Sherbondy, L. C. Chow, A. N. Leung, R. Mindelzun, P. K. Schraedley-Desmond, S. E. Zinck, D. P. Naidich, et al. Pulmonary Nodules on Multi-Detector Row CT Scans: Performance Comparison of Radiologists and Computer-aided Detection Radiology, January 1, 2005; 234(1): 274 - 283. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. R. Mayo, K.-I. Kim, S. L. S. MacDonald, T. Johkoh, P. Kavanagh, H. O. Coxson, and S. Vedal Reduced Radiation Dose Helical Chest CT: Effect on Reader Evaluation of Structures and Lung Findings Radiology, September 1, 2004; 232(3): 749 - 756. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. A. de Jong, M. D. Ottink, S. G. F. Robben, M. H. Lequin, W. C. J. Hop, J. J. E. Hendriks, P. D. Pare, and H. A. W. M. Tiddens Pulmonary Disease Assessment in Cystic Fibrosis: Comparison of CT Scoring Systems and Value of Bronchial and Arterial Dimension Measurements Radiology, May 1, 2004; 231(2): 434 - 439. [Abstract] [Full Text] [PDF] |
||||
![]() |
A J Britten, M Crotty, H Kiremidjian, A Grundy, and E J Adam The addition of computer simulated noise to investigate radiation dose and image quality in images with spatial correlation of statistical noise: an example application to X-ray CT of the brain Br. J. Radiol., April 1, 2004; 77(916): 323 - 328. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. Tack, V. De Maertelaer, and P. A. Gevenois Dose Reduction in Multidetector CT Using Attenuation-Based Online Tube Current Modulation Am. J. Roentgenol., August 1, 2003; 181(2): 331 - 334. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. A Yi, K. S. Lee, T. S. Kim, D. Han, Y. M. Sung, and S. Kim Multidetector CT of Bronchiectasis: Effect of Radiation Dose on Image Quality Am. J. Roentgenol., August 1, 2003; 181(2): 501 - 505. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. R. Mayo, J. Aldrich, and N. L. Muller Radiation Exposure at Chest CT: A Statement of the Fleischner Society Radiology, July 1, 2003; 228(1): 15 - 21. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. K. Kalra, C. Wittram, M. M. Maher, A. Sharma, G. B. Avinash, K. Karau, T. L. Toth, E. Halpern, S. Saini, and J.-A. Shepard Can Noise Reduction Filters Improve Low-Radiation-Dose Chest CT Images? Pilot Study Radiology, July 1, 2003; 228(1): 257 - 264. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. Hong, K. T. Bae, T. K. Pilgram, J. Suh, and D. Bradley Coronary Artery Calcium Measurement with Multi-Detector Row CT: In Vitro Assessment of Effect of Radiation Dose Radiology, December 1, 2002; 225(3): 901 - 906. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Itoh, M. Ikeda, Y. Mori, K. Suzuki, A. Sawaki, S. Iwano, H. Satake, S. Arahata, T. Isomura, M. Ozaki, et al. Lung: Feasibility of a Method for Changing Tube Current during Low-Dose Helical CT Radiology, September 1, 2002; 224(3): 905 - 912. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. F. Rogers Dose Reduction in CT: How Low Can We Go? Am. J. Roentgenol., August 1, 2002; 179(2): 299 - 299. [Full Text] [PDF] |
||||
![]() |
G Starck, L Lonn, A Cederblad, E Forssell-Aronsson, L Sjostrom, and M Alpsten A method to obtain the same levels of CT image noise for patients of various sizes, to minimize radiation dose Br. J. Radiol., February 1, 2002; 75(890): 140 - 150. [Abstract] [Full Text] [PDF] |
||||
![]() |
S J Golding and P C Shrimpton Radiation dose in CT: are we meeting the challenge? Br. J. Radiol., January 1, 2002; 75(889): 1 - 4. [Full Text] [PDF] |
||||
![]() |
J V Cook Radiation protection and quality assurance in paediatric radiology Imaging, December 1, 2001; 13(4): 229 - 238. [Abstract] [Full Text] [PDF] |
||||
![]() |
V Tsapaki, S Kottou, and D Papadimitriou Application of European Commission reference dose levels in CT examinations in Crete, Greece Br. J. Radiol., September 1, 2001; 74(885): 836 - 840. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. G. Ravenel, E. M. Scalzetti, W. Huda, and W. Garrisi Radiation Exposure and Image Quality in Chest CT Examinations Am. J. Roentgenol., August 1, 2001; 177(2): 279 - 284. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. L. Nickoloff and P. O. Alderson Radiation Exposures to Patients from CT: Reality, Public Perception, and Policy Am. J. Roentgenol., August 1, 2001; 177(2): 285 - 287. [Full Text] [PDF] |
||||
![]() |
J. R. Haaga Radiation Dose Management: Weighing Risk Versus Benefit Am. J. Roentgenol., August 1, 2001; 177(2): 289 - 291. [Full Text] [PDF] |
||||
![]() |
A. Paterson, D. P. Frush, and L. F. Donnelly Helical CT of the Body: Are Settings Adjusted for Pediatric Patients? Am. J. Roentgenol., February 1, 2001; 176(2): 297 - 301. [Abstract] [Full Text] [PDF] |
||||
![]() |
W. Huda, E. M. Scalzetti, and G. Levin Technique Factors and Image Quality as Functions of Patient Weight at Abdominal CT Radiology, November 1, 2000; 217(2): 430 - 435. [Abstract] [Full Text] |
||||
![]() |
M. Cohnen, H. Fischer, J. Hamacher, E. Lins, R. Kötter, and U. Mödder CT of the Head by Use of Reduced Current and Kilovoltage: Relationship between Image Quality and Dose Reduction AJNR Am. J. Neuroradiol., October 1, 2000; 21(9): 1654 - 1660. [Abstract] [Full Text] |
||||
![]() |
J. Lucaya, J. Piqueras, P. Garcia-Pena, G. Enriquez, M. Garcia-Macias, and J. Sotil Low-Dose High-Resolution CT of the Chest in Children and Young Adults: Dose, Cooperation, Artifact Incidence, and Image Quality Am. J. Roentgenol., October 1, 2000; 175(4): 985 - 992. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. E. Thomas, C. M. Owens, J. Britto, S. Nadel, P. Habibi, and R. Nicholson Efficacy of Chest CT in a Pediatric ICU : A Prospective Study Chest, June 1, 2000; 117(6): 1697 - 1705. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Itoh, M. Ikeda, S. Arahata, T. Kodaira, T. Isomura, T. Kato, K. Yamakawa, K. Maruyama, and T. Ishigaki Lung Cancer Screening: Minimum Tube Current Required for Helical CT Radiology, April 1, 2000; 215(1): 175 - 183. [Abstract] [Full Text] |
||||
![]() |
H. W. Venema, S. S. K. S. Phoa, P. G. B. Mirck, F. J. H. Hulsmans, C. B. L. M. Majoie, and B. Verbeeten Jr Petrosal Bone: Coronal Reconstructions from Axial Spiral CT Data Obtained with 0.5-mm Collimation Can Replace Direct Coronal Sequential CT Scans Radiology, November 1, 1999; 213(2): 375 - 382. [Abstract] [Full Text] |
||||
![]() |
T. H. Helbich, G. Heinz-Peer, I. Eichler, P. Wunderbaldinger, M. Götz, C. Wojnarowski, R. C. Brasch, and C. J. Herold Cystic Fibrosis: CT Assessment of Lung Involvement in Children and Adults Radiology, November 1, 1999; 213(2): 537 - 544. [Abstract] [Full Text] |
||||
![]() |
S. Diederich, H. Lenzen, R. Windmann, Z. Puskas, T. M. Yelbuz, S. Henneken, T. Klaiber, M. Eameri, N. Roos, and P. E. Peters Pulmonary Nodules: Experimental and Clinical Studies at Low-Dose CT Radiology, October 1, 1999; 213(1): 289 - 298. [Abstract] [Full Text] |
||||
![]() |
D. E. Ware, W. Huda, P. J. Mergo, and A. L. Litwiller Radiation Effective Doses to Patients Undergoing Abdominal CT Examinations Radiology, March 1, 1999; 210(3): 645 - 650. [Abstract] [Full Text] |
||||