AJR ARRS Membership
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kerns, S. R.
Right arrow Articles by Hawkins, I. F.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kerns, S. R.
Right arrow Articles by Hawkins, I. F., Jr
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?

American Journal of Roentgenology, Vol 164, 735-741, Copyright © 1995 by American Roentgen Ray Society


ARTICLES

Carbon dioxide digital subtraction angiography: expanding applications and technical evolution

SR Kerns and IF Hawkins Jr
Department of Radiology, University of Florida, Gainesville 32610.

Although several noninvasive techniques now exist for vascular imaging, including MR imaging, three-dimensional CT, and color-flow and duplex sonography, the gold standard to which these techniques are compared remains catheter angiography. Cut-film and digital subtraction angiography (DSA) using iodinated contrast material are the standard methods by which vascular imaging is performed. However, despite the development of low-osmolar contrast agents, premedication regimens, and careful patient selection, adverse reactions to contrast material, including idiosyncratic reactions and contrast-induced nephropathy, continue to occur in a small number of patients [1-3]. Carbon dioxide (CO2) was developed as an alternative to iodinated contrast material to avoid these problems [4]. Once the behavior of intravascular gas, the methods of safe delivery, and the principles of successful imaging are understood, the use of CO2 as an intravascular contrast agent during DSA allows accurate imaging with little risk. Recent advances in delivery systems, postprocessing capabilities, and its extension to new vascular interventional procedures have greatly expanded the usefulness of CO2 angiography in both diagnostic and interventional vascular radiology.
Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
RadiologyHome page
S. Heye, G. Maleux, and G. J. Marchal
Upper-Extremity Venography: CO2 versus Iodinated Contrast Material
Radiology, October 1, 2006; 241(1): 291 - 297.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
F. K. Wacker, R. M. Maes, J. A. Jesberger, S. G. Nour, J. L. Duerk, and J. S. Lewin
MR Imaging-Guided Vascular Procedures Using CO2 as a Contrast Agent
Am. J. Roentgenol., August 1, 2003; 181(2): 485 - 489.
[Abstract] [Full Text] [PDF]


Home page
Nephrol Dial TransplantHome page
J. Rieger, T. Sitter, M. Toepfer, U. Linsenmaier, K. J. Pfeifer, and H. Schiffl
Gadolinium as an alternative contrast agent for diagnostic and interventional angiographic procedures in patients with impaired renal function
Nephrol. Dial. Transplant., May 1, 2002; 17(5): 824 - 828.
[Abstract] [Full Text] [PDF]


Home page
ImagingHome page
D O Kessel, I Robertson, J V Patel, S Simpson, and E J Taylor
Angiographic strategies when iodinated contrast medium is undesirable
Imaging, December 15, 2001; 13(5): 349 - 356.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
L. Miskolczi, J. D. Flaherty, L. R. Guterman, and L. N. Hopkins
Carbon Dioxide Column Angioscopy: A New Endovascular Imaging Technique
AJNR Am. J. Neuroradiol., November 1, 2001; 22(10): 1849 - 1853.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
I. F. Hawkins Jr., J. G. Caridi, S. D. Klioze, and C. R. J. Mladinich
Modified Plastic Bag System with O-Ring Fitting Connection for Carbon Dioxide Angiography
Am. J. Roentgenol., January 1, 2001; 176(1): 229 - 232.
[Full Text]


Home page
GutHome page
W Debernardi-Venon, J-C Bandi, J-C Garcia-Pagan, E Moitinho, V Andreu, M Real, A Escorsell, X Montanya, and J Bosch
CO2 wedged hepatic venography in the evaluation of portal hypertension
Gut, June 1, 2000; 46(6): 856 - 860.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
J. A. Kaufman, S. C. Geller, H. Bazari, and A. C. Waltman
Gadolinium-based Contrast Agents as an Alternative at Vena Cavography in Patients with Renal Insufficiency—Early Experience
Radiology, July 1, 1999; 212(1): 280 - 284.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1995 by the American Roentgen Ray Society.