American Journal of Roentgenology, Vol 165, 53-55, Copyright © 1995 by American Roentgen Ray Society
ARTICLES |
LB Haramati
Department of Radiology, Albert Einstein College of Medicine, Bronx, NY 10461, USA.
OBJECTIVE. The purpose of this study was to determine the diagnostic accuracy and frequency of complications of CT-guided transthoracic needle biopsy done with an automated biopsy system. MATERIALS AND METHODS. Thirty-three consecutive biopsies were performed on 32 patients between February 1992 and July 1994 (mean age, 55 +/- 15 years; 18 men and 14 women). An 18-gauge (n = 28) or 20-gauge (n = 5) needle was used. Core specimens were submitted for pathologic examination in 10% formalin. No cytopathologist or frozen section analysis was available at the time of biopsy. All biopsies but one were performed by one chest radiologist. RESULTS. Thirty-one lung biopsies and two mediastinal biopsies yielded a mean lesion size of 4.0 cm (range, 1.2-13.0 cm). Postbiopsy pneumothorax occurred in three (9%) of 33 biopsies; none of the pneumothoraces required placement of a chest tube. The mean number of needle passes was 1.3 (+/- 0.6). Thirty biopsies (91%) yielded sufficient tissue for pathologic evaluation. The diagnoses included carcinoma in 14 cases, acute or chronic pneumonia in 4 cases, non-Hodgkin's lymphoma in two cases, and Kaposi's sarcoma, plasma cell granuloma, hypersensitivity pneumonitis, Pneumocystis carinii pneumonia, and fibrosis in one case each. One patient with a 1.5-cm nodule stable for 1 year on CT had fibrosis and chronic inflammation found on needle biopsy, and the nodule was considered benign. Overall, biopsies in 12 (80%) of 15 patients without carcinoma were diagnostic. In three patients, the tissue obtained was not representative of the underlying abnormality. The biopsy specimen showed only inflammatory changes in two patients who ultimately had proved carcinoma. One patient with multiple pulmonary infarcts due to tumor emboli showed evidence of only pulmonary infarct on biopsy. Three patients had insufficient tissue for analysis; none of the three had malignant tumor on follow-up. The sensitivity of CT-guided automated needle biopsy of the chest was 84%. CONCLUSION. CT-guided transthoracic needle biopsy of the chest done with an automated biopsy system is safe, with a pneumothorax rate comparable to that of skinny needle aspiration. An overall accurate tissue diagnosis was made in 26 (81%) of 32 patients. Biopsies in 12 (80%) of 15 patients without carcinoma were diagnostic, which compares favorably with the reported accuracy of skinny needle aspiration.
This article has been cited by other articles:
![]() |
R YOSHIMATSU, T YAMAGAMI, T KATO, T HIROTA, T MATSUMOTO, J SHIMADA, and T NISHIMURA Percutaneous needle biopsy of lung nodules under CT fluoroscopic guidance with use of the "I-I device" Br. J. Radiol., February 1, 2008; 81(962): 107 - 112. [Abstract] [Full Text] [PDF] |
||||
![]() |
Y-C. Chang, C-J. Yu, W-J. Lee, S-H. Kuo, C-H. Hsiao, I-S. Jan, F-C. Hu, H-M. Liu, W-K. Chan, and P-C. Yang Imprint cytology improves accuracy of computed tomography-guided percutaneous transthoracic needle biopsy Eur. Respir. J., January 1, 2008; 31(1): 54 - 61. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. Matsuguma, R. Nakahara, T. Kondo, Y. Kamiyama, K. Mori, and K. Yokoi Risk of Pleural Recurrence After Needle Biopsy in Patients With Resected Early Stage Lung Cancer Ann. Thorac. Surg., December 1, 2005; 80(6): 2026 - 2031. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. Loubeyre, M. Copercini, and P.-Y. Dietrich Percutaneous CT-Guided Multisampling Core Needle Biopsy of Thoracic Lesions Am. J. Roentgenol., November 1, 2005; 185(5): 1294 - 1298. [Abstract] [Full Text] [PDF] |
||||
![]() |
W-Y. Liao, J-S. Jerng, K-Y. Chen, Y-L. Chang, P-C. Yang, and S-H. Kuo Value of imprint cytology for ultrasound-guided transthoracic core biopsy Eur. Respir. J., December 1, 2004; 24(6): 905 - 909. [Abstract] [Full Text] [PDF] |
||||
![]() |
D R Baldwin, J D Birchall, R H Ganatra, and K S Pointon Evaluation of the solitary pulmonary nodule: clinical management, role of CT and nuclear medicine Imaging, October 1, 2004; 16(1): 22 - 36. [Abstract] [Full Text] [PDF] |
||||
![]() |
V. S. Chandan, K. Zimmerman, P. Baker, E. Scalzetti, and K. K. Khurana Usefulness of Core Roll Preparations in Immediate Assessment of Neoplastic Lung Lesions: Comparison to Conventional CT Scan-Guided Lung Fine-Needle Aspiration Cytology Chest, September 1, 2004; 126(3): 739 - 743. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Yamagami, T. Kato, S. Iida, T. Hirota, and T. Nishimura Percutaneous Needle Biopsy for Small Lung Nodules Beneath the Rib Under CT Scan Fluoroscopic Guidance With Gantry Tilt Chest, September 1, 2004; 126(3): 744 - 747. [Abstract] [Full Text] [PDF] |
||||
![]() |
K.-M. Yeow, I-H. Su, K.-T. Pan, P.-K. Tsay, K.-W. Lui, Y.-C. Cheung, and A. S.-B. Chou Risk Factors of Pneumothorax and Bleeding: Multivariate Analysis of 660 CT-Guided Coaxial Cutting Needle Lung Biopsies Chest, September 1, 2004; 126(3): 748 - 754. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Yamagami, S. Iida, T. Kato, O. Tanaka, S. Toda, D. Kato, and T. Nishimura Usefulness of New Automated Cutting Needle for Tissue-Core Biopsy of Lung Nodules Under CT Fluoroscopic Guidance Chest, July 1, 2003; 124(1): 147 - 154. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Yamagami, S. Iida, T. Kato, O. Tanaka, and T. Nishimura Combining Fine-Needle Aspiration and Core Biopsy Under CT Fluoroscopy Guidance: A Better Way to Treat Patients with Lung Nodules? Am. J. Roentgenol., March 1, 2003; 180(3): 811 - 815. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. B. Haramati and G. Aviram What Constitutes Effective Management of Pneumothorax After CT-Guided Needle Biopsy of the Lung? Chest, April 1, 2002; 121(4): 1013 - 1015. [Full Text] [PDF] |
||||
![]() |
H. Tsukada, T. Satou, A. Iwashima, and T. Souma Diagnostic Accuracy of CT-Guided Automated Needle Biopsy of Lung Nodules Am. J. Roentgenol., July 1, 2000; 175(1): 239 - 243. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Hirose, K. Mori, S. Machida, K. Tominaga, K. Yokoi, and M. Adachi Computed Tomographic Fluoroscopy-guided Transthoracic Needle Biopsy for Diagnosis of Pulmonary Nodules Jpn. J. Clin. Oncol., June 1, 2000; 30(6): 259 - 262. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. Shaffer Role of Radiology for Imaging and Biopsy of Solitary Pulmonary Nodules* Chest, December 1, 1999; 116(suppl_3): 519S - 522S. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |