AJR ARRS Membership
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Haramati, L. B.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Haramati, L. B.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?

American Journal of Roentgenology, Vol 165, 53-55, Copyright © 1995 by American Roentgen Ray Society


ARTICLES

CT-guided automated needle biopsy of the chest

LB Haramati
Department of Radiology, Albert Einstein College of Medicine, Bronx, NY 10461, USA.

OBJECTIVE. The purpose of this study was to determine the diagnostic accuracy and frequency of complications of CT-guided transthoracic needle biopsy done with an automated biopsy system. MATERIALS AND METHODS. Thirty-three consecutive biopsies were performed on 32 patients between February 1992 and July 1994 (mean age, 55 +/- 15 years; 18 men and 14 women). An 18-gauge (n = 28) or 20-gauge (n = 5) needle was used. Core specimens were submitted for pathologic examination in 10% formalin. No cytopathologist or frozen section analysis was available at the time of biopsy. All biopsies but one were performed by one chest radiologist. RESULTS. Thirty-one lung biopsies and two mediastinal biopsies yielded a mean lesion size of 4.0 cm (range, 1.2-13.0 cm). Postbiopsy pneumothorax occurred in three (9%) of 33 biopsies; none of the pneumothoraces required placement of a chest tube. The mean number of needle passes was 1.3 (+/- 0.6). Thirty biopsies (91%) yielded sufficient tissue for pathologic evaluation. The diagnoses included carcinoma in 14 cases, acute or chronic pneumonia in 4 cases, non-Hodgkin's lymphoma in two cases, and Kaposi's sarcoma, plasma cell granuloma, hypersensitivity pneumonitis, Pneumocystis carinii pneumonia, and fibrosis in one case each. One patient with a 1.5-cm nodule stable for 1 year on CT had fibrosis and chronic inflammation found on needle biopsy, and the nodule was considered benign. Overall, biopsies in 12 (80%) of 15 patients without carcinoma were diagnostic. In three patients, the tissue obtained was not representative of the underlying abnormality. The biopsy specimen showed only inflammatory changes in two patients who ultimately had proved carcinoma. One patient with multiple pulmonary infarcts due to tumor emboli showed evidence of only pulmonary infarct on biopsy. Three patients had insufficient tissue for analysis; none of the three had malignant tumor on follow-up. The sensitivity of CT-guided automated needle biopsy of the chest was 84%. CONCLUSION. CT-guided transthoracic needle biopsy of the chest done with an automated biopsy system is safe, with a pneumothorax rate comparable to that of skinny needle aspiration. An overall accurate tissue diagnosis was made in 26 (81%) of 32 patients. Biopsies in 12 (80%) of 15 patients without carcinoma were diagnostic, which compares favorably with the reported accuracy of skinny needle aspiration.
Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
Br. J. Radiol.Home page
R YOSHIMATSU, T YAMAGAMI, T KATO, T HIROTA, T MATSUMOTO, J SHIMADA, and T NISHIMURA
Percutaneous needle biopsy of lung nodules under CT fluoroscopic guidance with use of the "I-I device"
Br. J. Radiol., February 1, 2008; 81(962): 107 - 112.
[Abstract] [Full Text] [PDF]


Home page
Eur Respir JHome page
Y-C. Chang, C-J. Yu, W-J. Lee, S-H. Kuo, C-H. Hsiao, I-S. Jan, F-C. Hu, H-M. Liu, W-K. Chan, and P-C. Yang
Imprint cytology improves accuracy of computed tomography-guided percutaneous transthoracic needle biopsy
Eur. Respir. J., January 1, 2008; 31(1): 54 - 61.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
H. Matsuguma, R. Nakahara, T. Kondo, Y. Kamiyama, K. Mori, and K. Yokoi
Risk of Pleural Recurrence After Needle Biopsy in Patients With Resected Early Stage Lung Cancer
Ann. Thorac. Surg., December 1, 2005; 80(6): 2026 - 2031.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
P. Loubeyre, M. Copercini, and P.-Y. Dietrich
Percutaneous CT-Guided Multisampling Core Needle Biopsy of Thoracic Lesions
Am. J. Roentgenol., November 1, 2005; 185(5): 1294 - 1298.
[Abstract] [Full Text] [PDF]


Home page
Eur Respir JHome page
W-Y. Liao, J-S. Jerng, K-Y. Chen, Y-L. Chang, P-C. Yang, and S-H. Kuo
Value of imprint cytology for ultrasound-guided transthoracic core biopsy
Eur. Respir. J., December 1, 2004; 24(6): 905 - 909.
[Abstract] [Full Text] [PDF]


Home page
ImagingHome page
D R Baldwin, J D Birchall, R H Ganatra, and K S Pointon
Evaluation of the solitary pulmonary nodule: clinical management, role of CT and nuclear medicine
Imaging, October 1, 2004; 16(1): 22 - 36.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
V. S. Chandan, K. Zimmerman, P. Baker, E. Scalzetti, and K. K. Khurana
Usefulness of Core Roll Preparations in Immediate Assessment of Neoplastic Lung Lesions: Comparison to Conventional CT Scan-Guided Lung Fine-Needle Aspiration Cytology
Chest, September 1, 2004; 126(3): 739 - 743.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
T. Yamagami, T. Kato, S. Iida, T. Hirota, and T. Nishimura
Percutaneous Needle Biopsy for Small Lung Nodules Beneath the Rib Under CT Scan Fluoroscopic Guidance With Gantry Tilt
Chest, September 1, 2004; 126(3): 744 - 747.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
K.-M. Yeow, I-H. Su, K.-T. Pan, P.-K. Tsay, K.-W. Lui, Y.-C. Cheung, and A. S.-B. Chou
Risk Factors of Pneumothorax and Bleeding: Multivariate Analysis of 660 CT-Guided Coaxial Cutting Needle Lung Biopsies
Chest, September 1, 2004; 126(3): 748 - 754.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
T. Yamagami, S. Iida, T. Kato, O. Tanaka, S. Toda, D. Kato, and T. Nishimura
Usefulness of New Automated Cutting Needle for Tissue-Core Biopsy of Lung Nodules Under CT Fluoroscopic Guidance
Chest, July 1, 2003; 124(1): 147 - 154.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
T. Yamagami, S. Iida, T. Kato, O. Tanaka, and T. Nishimura
Combining Fine-Needle Aspiration and Core Biopsy Under CT Fluoroscopy Guidance: A Better Way to Treat Patients with Lung Nodules?
Am. J. Roentgenol., March 1, 2003; 180(3): 811 - 815.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
L. B. Haramati and G. Aviram
What Constitutes Effective Management of Pneumothorax After CT-Guided Needle Biopsy of the Lung?
Chest, April 1, 2002; 121(4): 1013 - 1015.
[Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
H. Tsukada, T. Satou, A. Iwashima, and T. Souma
Diagnostic Accuracy of CT-Guided Automated Needle Biopsy of Lung Nodules
Am. J. Roentgenol., July 1, 2000; 175(1): 239 - 243.
[Abstract] [Full Text] [PDF]


Home page
Jpn J Clin OncolHome page
T. Hirose, K. Mori, S. Machida, K. Tominaga, K. Yokoi, and M. Adachi
Computed Tomographic Fluoroscopy-guided Transthoracic Needle Biopsy for Diagnosis of Pulmonary Nodules
Jpn. J. Clin. Oncol., June 1, 2000; 30(6): 259 - 262.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
K. Shaffer
Role of Radiology for Imaging and Biopsy of Solitary Pulmonary Nodules*
Chest, December 1, 1999; 116(suppl_3): 519S - 522S.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1995 by the American Roentgen Ray Society.