|
|
||||||||
American Journal of Roentgenology, Vol 165, 1079-1088, Copyright © 1995 by American Roentgen Ray Society
ARTICLES |
RK Zeman, PM Silverman, PT Vieco and P Costello
Department of Radiology, Georgetown University Medical Center, Washington, DC 20007, USA.
CT angiography is an exciting yet controversial application of helical (spiral) CT technology. Although many radiologists equate CT angiography with three-dimensional (3D) rendering, we believe that axial images, multiplanar reformatted (MPR) images, and true 3D models all contribute to a better evaluation of the vascular system than was possible with conventional CT. This occurs because helical scans are volumetric and are accomplished rapidly with high levels of circulating contrast material. This article reviews the indications for CT angiography, compares CT angiography with other techniques, and offers a practical methodology for neuroradiologic, thoracic, and abdominal applications of CT angiography.
This article has been cited by other articles:
![]() |
L. P. Lawler and E. K. Fishman Multi-Detector Row CT of Thoracic Disease with Emphasis on 3D Volume Rendering and CT Angiography RadioGraphics, September 1, 2001; 21(5): 1257 - 1273. [Abstract] [Full Text] [PDF] |
||||
![]() |
G.R. Ferretti, I. Bricault, and M. Coulomb Virtual tools for imaging of the thorax Eur. Respir. J., August 1, 2001; 18(2): 381 - 392. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. B. Bederson, I. A. Awad, D. O. Wiebers, D. Piepgras, E. C. Haley Jr, T. Brott, G. Hademenos, D. Chyatte, R. Rosenwasser, and C. Caroselli Recommendations for the Management of Patients With Unruptured Intracranial Aneurysms : A Statement for Healthcare Professionals From the Stroke Council of the American Heart Association Stroke, November 1, 2000; 31(11): 2742 - 2750. [Full Text] [PDF] |
||||
![]() |
J. B. Bederson, I. A. Awad, D. O. Wiebers, D. Piepgras, E. C. Haley Jr, T. Brott, G. Hademenos, D. Chyatte, R. Rosenwasser, and C. Caroselli Recommendations for the Management of Patients With Unruptured Intracranial Aneurysms : A Statement for Healthcare Professionals From the Stroke Council of the American Heart Association Circulation, October 31, 2000; 102(18): 2300 - 2308. [Full Text] [PDF] |
||||
![]() |
T. Brandt, M. Knauth, S. Wildermuth, R. Winter, R. von Kummer, K. Sartor, and W. Hacke CT Angiography and Doppler Sonography for Emergency Assessment in Acute Basilar Artery Ischemia Stroke, March 1, 1999; 30(3): 606 - 612. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. A. Alberico, P. Barnes, R. L. Robertson, and P. E. Burrows Helical CT Angiography: Dynamic Cerebrovascular Imaging in Children AJNR Am. J. Neuroradiol., February 1, 1999; 20(2): 328 - 334. [Abstract] [Full Text] |
||||
![]() |
R. Raman, S. Napel, C. F. Beaulieu, E. S. Bain, R. B. Jeffrey Jr, and G. D. Rubin Automated Generation of Curved Planar Reformations from Volume Data: Method and Evaluation Radiology, April 1, 2002; 223(1): 275 - 280. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |