American Journal of Roentgenology, Vol 166, 73-77, Copyright © 1996 by American Roentgen Ray Society
ARTICLES |
WW Mayo-Smith, S Saini, G Slater, JA Kaufman, P Sharma and PF Hahn
Department of Radiology, Massachusetts General Hospital, Boston 02114, USA.
OBJECTIVE. The purpose of this study were to quantify abdominal vascular enhancement and to prove the feasibility of iron oxide- enhanced MR angiography in humans using three doses of superparamagnetic iron oxide agent AMI 227. SUBJECTS AND METHODS. Sixteen patients randomly received either 0.8, 1.1, or 1.7 mg Fe/kg of ultrasmall superparamagnetic iron oxide agent AMI 227. T1-weighted breath-hold gradient-echo images were obtained before and 45 min after i.v. administration of AMI 227. Signal intensity was measured in the aorta, the inferior vena cava, the portal vein, and muscle on unenhanced and contrast-enhanced images. Signal-to-noise ratios and enhancement [(SNR after contrast-SNR before contrast) / SNR before contrast] were calculated. Vessels were visually graded before and after administration of AMI 227. RESULTS. All vessels showed statistically significant enhancement 45 min. after administration of AMI 227 by both qualitative and quantitative measures (p < .001). There was no significant increase in noise or signal intensity of muscle after contrast material was administered. The amount of enhancement was not statistically significantly different among the three doses. CONCLUSIONS. AMI 227, which is currently in phase III clinical trials, demonstrates significant vascular enhancement and may prove useful as an MR angiographic contrast agent.
This article has been cited by other articles:
![]() |
H. Ersoy, P. Jacobs, C. K. Kent, and M. R. Prince Blood Pool MR Angiography of Aortic Stent-Graft Endoleak Am. J. Roentgenol., May 1, 2004; 182(5): 1181 - 1186. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. Reimer, C. Bremer, T. Allkemper, M. Engelhardt, M. Mahler, W. Ebert, and B. Tombach Myocardial Perfusion and MR Angiography of Chest with SH U 555 C: Results of Placebo-controlled Clinical Phase I Study Radiology, May 1, 2004; 231(2): 474 - 481. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. K. Wacker, K. Reither, W. Ebert, M. Wendt, J. S. Lewin, and K.-J. Wolf MR Image-guided Endovascular Procedures with the Ultrasmall Superparamagnetic Iron Oxide SH U 555 C as an Intravascular Contrast Agent: Study in Pigs Radiology, February 1, 2003; 226(2): 459 - 464. [Abstract] [Full Text] [PDF] |
||||
![]() |
E.-M. Larsson, P. Sunden, C.-G. Olsson, J. Debatin, A. J. Duerinckx, R. Baum, D. Hahn, and F. Ebner MR Venography Using an Intravascular Contrast Agent: Results from a Multicenter Phase 2 Study of Dosage Am. J. Roentgenol., January 1, 2003; 180(1): 227 - 232. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. J. Kroencke, M. N. Wasser, P. M. T. Pattynama, J. O. Barentsz, E. Grabbe, G. Marchal, M. V. Knopp, G. Schneider, L. Bonomo, D. J. Pennell, et al. Gadobenate Dimeglumine--Enhanced MR Angiography of the Abdominal Aorta and Renal Arteries Am. J. Roentgenol., December 1, 2002; 179(6): 1573 - 1582. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. Waller, E. Kahler, K.-H. Hiller, K. Hu, M. Nahrendorf, S. Voll, A. Haase, G. Ertl, and W. R. Bauer Myocardial Perfusion and Intracapillary Blood Volume in Rats at Rest and with Coronary Dilatation: MR Imaging in Vivo with Use of a Spin-Labeling Technique Radiology, April 1, 2000; 215(1): 189 - 197. [Abstract] [Full Text] |
||||
![]() |
S. E. Clarke, H.-J. Weinmann, E. Dai, A. R. Lucas, and B. K. Rutt Comparison of Two Blood Pool Contrast Agents for 0.5-T MR Angiography: Experimental Study in Rabbits Radiology, March 1, 2000; 214(3): 787 - 794. [Abstract] [Full Text] |
||||
![]() |
E. K. Yucel, C. M. Anderson, R. R. Edelman, T. M. Grist, R. A. Baum, W. J. Manning, A. Culebras, and W. Pearce Magnetic Resonance Angiography : Update on Applications for Extracranial Arteries Circulation, November 30, 1999; 100(22): 2284 - 2301. [Full Text] [PDF] |
||||
![]() |
S. A. Schmitz, T. Albrecht, and K.-J. Wolf MR Angiography with Superparamagnetic Iron Oxide: Feasibility Study Radiology, October 1, 1999; 213(2): 603 - 607. [Abstract] [Full Text] |
||||
![]() |
K. H. Ahlström, L. O. Johansson, J. B. Rodenburg, A. S. Ragnarsson, P. Åkeson, and A. Börseth Pulmonary MR Angiography with Ultrasmall Superparamagnetic Iron Oxide Particles as a Blood Pool Agent and a Navigator Echo for Respiratory Gating: Pilot Study Radiology, June 1, 1999; 211(3): 865 - 869. [Abstract] [Full Text] |
||||
![]() |
T. Allkemper, C. Bremer, L. Matuszewski, W. Ebert, and P. Reimer Contrast-enhanced Blood-Pool MR Angiography with Optimized Iron Oxides: Effect of Size and Dose on Vascular Contrast Enhancement in Rabbits Radiology, May 1, 2002; 223(2): 432 - 438. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |