|
|
||||||||
American Journal of Roentgenology, Vol 166, 341-346, Copyright © 1996 by American Roentgen Ray Society
ARTICLES |
RJ Brenner, L Fajardo, PR Fisher, DD Dershaw, WP Evans, L Bassett, S Feig, E Mendelson, V Jackson and FR Margolin
Eisenberg Keefer Breast Center, Saint John's Hospital and Health Center, Santa Monica, CA 90404, USA.
OBJECTIVE: The purpose of our study was to assess the degree of operator experience and the number of core biopsy samples required to achieve an accurate histologic diagnosis for each of five common mammographically defined lesions, using percutaneous core breast biopsy performed on a dedicated prone biopsy table. SUBJECTS AND METHODS: A prospective multisite study was performed that involved nine institutions (academic and private) with experienced breast radiologists and the use of dedicated prone biopsy table units with digital assistance and standardized protocol. Asymptomatic women evaluated during a 2-year study period were assigned a mammographic diagnosis reported in a manner prescribed by the American College of Radiology Breast Imaging Reporting and Data System lexicon. Mammographic lesions evaluated included masses, masses with calcifications, clustered calcifications, focal asymmetries, and architectural distortions. Where histologic diagnosis was indicated, core biopsy was performed with five individual samples obtained and sequentially analyzed. Two hundred thirty patients had immediate excisional biopsy, the results of which provided the basis for a statistical analysis to compare the accuracy of each sequential core biopsy sample with surgical results. Statistical analysis was also done to ascertain the accuracy of core biopsy diagnosis as a function of operator experience. RESULTS: Trends toward increasing accuracy were observed by increasing the number of core biopsies for each of five types of mammographically defined lesions, especially for clustered calcifications. Statistically significant increased accuracy was observed when the number of biopsies was increased beyond one (p = .003). Trends toward increased accuracy with more experience were observed for all lesions, especially for calcifications. Of the 230 lesions studied with immediate surgical validation, more than 80% of all lesions except clustered calcifications (75%) were diagnosed on the basis of two core biopsies; accuracy after five biopsies was 98% for masses, 91% for calcifications, 100% for masses with calcification, 100% for focal asymmetries, and 86% for architectural distortions. CONCLUSIONS: Accuracy of diagnosis based on the results of percutaneous core breast biopsy improved with an increase in the number of core biopsy samples obtained for any given lesion seen on mammograms and with increased experience in performing the procedure. Five samples yielded an overall diagnostic accuracy of 97%. Familiarity with expected accuracy from this procedure for different mammographic lesions and following increased experience may assist physicians in planning patient management.
This article has been cited by other articles:
![]() |
E A Rakha and I O Ellis An overview of assessment of prognostic and predictive factors in breast cancer needle core biopsy specimens J. Clin. Pathol., December 1, 2007; 60(12): 1300 - 1306. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. F. Dillon, E. W. McDermott, A. D. Hill, A. O'Doherty, N. O'Higgins, and C. M. Quinn Predictive Value of Breast Lesions of "Uncertain Malignant Potential" and "Suspicious for Malignancy" Determined by Needle Core Biopsy Ann. Surg. Oncol., February 1, 2007; 14(2): 704 - 711. [Abstract] [Full Text] [PDF] |
||||
![]() |
M F Dillon, C M Quinn, E W McDermott, A O'Doherty, N O'Higgins, and A D K Hill Diagnostic accuracy of core biopsy for ductal carcinoma in situ and its implications for surgical practice. J. Clin. Pathol., July 1, 2006; 59(7): 740 - 743. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. K. Koskela, M. Sudah, M. H. Berg, V. J. Karja, P. K. Mustonen, V. Kataja, and R. S. Vanninen Add-on Device for Stereotactic Core-Needle Breast Biopsy: How Many Biopsy Specimens Are Needed for a Reliable Diagnosis? Radiology, September 1, 2005; 236(3): 801 - 809. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. J. Kirshenbaum, T. Voruganti, C. Overbeeke, M. D. Kirshenbaum, P. Patel, G. Kaplan, V. Maker, C. August, and R. P. Cavallino Stereotactic Core Needle Biopsy of Nonpalpable Breast Lesions Using a Conventional Mammography Unit with an Add-On Device Am. J. Roentgenol., August 1, 2003; 181(2): 527 - 531. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. E. Fishman, C. Milikowski, R. Ramsinghani, M. V. Velasquez, and G. Aviram US-guided Core-Needle Biopsy of the Breast: How Many Specimens Are Necessary? Radiology, March 1, 2003; 226(3): 779 - 782. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. J. Brenner, R. J. Jackman, S. H. Parker, W. P. Evans III, L. Philpotts, B. M. Deutch, M. C. Lechner, D. Lehrer, P. Sylvan, R. Hunt, et al. Percutaneous Core Needle Biopsy of Radial Scars of the Breast: When Is Excision Necessary? Am. J. Roentgenol., November 1, 2002; 179(5): 1179 - 1184. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. Wunderbaldinger, G. Wolf, K. Turetschek, and T. H. Helbich Comparison of Sitting Versus Prone Position for Stereotactic Large-Core Breast Biopsy in Surgically Proven Lesions Am. J. Roentgenol., May 1, 2002; 178(5): 1221 - 1225. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. Georgian-Smith, C. D'Orsi, E. Morris, C. F. Clark Jr., E. Liberty, and C. D. Lehman Stereotactic Biopsy of the Breast Using an Upright Unit, a Vacuum-Suction Needle, and a Lateral Arm-Support System Am. J. Roentgenol., April 1, 2002; 178(4): 1017 - 1024. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. Becker, D. Taves, L. McCurdy, G. Muscedere, S. Karlik, and S. Ward Stereotactic Core Biopsy of Breast Microcalcifications: Comparison of Film Versus Digital Mammography, Both Using an Add-On Unit Am. J. Roentgenol., December 1, 2001; 177(6): 1451 - 1457. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. R. Margolin, J. W. T. Leung, R. P. Jacobs, and S. R. Denny Percutaneous Imaging-Guided Core Breast Biopsy: 5 Years' Experience in a Community Hospital Am. J. Roentgenol., September 1, 2001; 177(3): 559 - 564. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. K. Kuhl, N. Morakkabati, C. C. Leutner, A. Schmiedel, E. Wardelmann, and H. H. Schild MR Imaging-guided Large-Core (14-Gauge) Needle Biopsy of Small Lesions Visible at Breast MR Imaging Alone Radiology, July 1, 2001; 220(1): 31 - 39. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. Liberman, C. L. Benton, D. D. Dershaw, A. F. Abramson, L. R. LaTrenta, and E. A. Morris Learning Curve for Stereotactic Breast Biopsy: How Many Cases Are Enough? Am. J. Roentgenol., March 1, 2001; 176(3): 721 - 727. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. J. Brenner, L. W. Bassett, L. L. Fajardo, D. D. Dershaw, W. P. Evans III, R. Hunt, C. Lee, I. Tocino, P. Fisher, M. McCombs, et al. Stereotactic Core-Needle Breast Biopsy: A Multi-institutional Prospective Trial Radiology, March 1, 2001; 218(3): 866 - 872. [Abstract] [Full Text] |
||||
![]() |
L. E. Philpotts, C. H. Lee, L. J. Horvath, R. C. Lange, D. Carter, and I. Tocino Underestimation of Breast Cancer with II-Gauge Vacuum Suction Biopsy Am. J. Roentgenol., October 1, 2000; 175(4): 1047 - 1050. [Abstract] [Full Text] [PDF] |
||||
![]() |
W. E. Burak Jr, K. E. Owens, M. B. Tighe, L. Kemp, S. A. Dinges, C. L. Hitchcock, and J. Olsen Vacuum-Assisted Stereotactic Breast Biopsy: Histologic Underestimation of Malignant Lesions Arch Surg, June 1, 2000; 135(6): 700 - 703. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. Liberman Percutaneous Imaging-Guided Core Breast Biopsy: State of the Art at the Millennium Am. J. Roentgenol., May 1, 2000; 174(5): 1191 - 1199. [Full Text] [PDF] |
||||
![]() |
R. J. Brenner Lesions Entirely Removed during Stereotactic Biopsy: Preoperative Localization on the Basis of Mammographic Landmarks and Feasibility of Freehand Technique-Initial Experience Radiology, February 1, 2000; 214(2): 585 - 590. [Abstract] [Full Text] |
||||
![]() |
R. J. Jackman, K. W. Nowels, J. Rodriguez-Soto, F. A. Marzoni Jr, S. I. Finkelstein, and M. J. Shepard Stereotactic, Automated, Large-Core Needle Biopsy of Nonpalpable Breast Lesions: False-Negative and Histologic Underestimation Rates after Long-term Follow-up Radiology, March 1, 1999; 210(3): 799 - 805. [Abstract] [Full Text] |
||||
![]() |
H. Seoudi, J. Mortier, R. Basile, and E. Curletti Stereotactic Core Needle Biopsy of Nonpalpable Breast Lesions: Initial Experience With a Promising Technique Arch Surg, April 1, 1998; 133(4): 366 - 372. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |