American Journal of Roentgenology, Vol 166, 593-597, Copyright © 1996 by American Roentgen Ray Society
ARTICLES |
P Soyer, S Le Normand, SC de Givry, C Gueye, E Somveille and A Scherrer
Department of Radiology, Hopital Foch, France.
OBJECTIVE: The goal of our study was to compare a T2-weighted breath- hold fast spin-echo (BHSE) technique with T2-weighted non-breath-hold fast spin-echo techniques for imaging the liver. SUBJECTS AND METHODS: Thirty-three patients with hepatic lesions had T2-weighted BHSE images obtained in 22 sec and conventional T2-weighted non-breath-hold fast spin-echo images obtained in 3 min 12 sec with and without fat suppression. Images were analyzed quantitatively by measuring the lesion-liver contrast, spleen-liver contrast, and signal-to-noise ratios of lesions and qualitatively by evaluating the sharpness of hepatic contours, visibility of intrahepatic vessels and other segmental landmarks, and presence of artifacts. RESULTS: Quantitatively, lesion-liver contrast, spleen-liver contrast, and signal-to-noise ratios obtained with the BHSE technique were inferior to those obtained with fast spin-echo techniques with and without fat suppression (11.2 +/- 7.1 versus 15.4 +/- 10.6 and 14.5 +/- 9.8, p < .001; 5.3 +/- 3.7 versus 8.7 +/- 3.5 and 7.0 +/- 3.8, p < .001; 16.2 +/- 8.2 versus 20.1 +/- 10.9 and 19.7 +/- 9.5, p < .01, respectively; Student's t test). Qualitatively, image artifacts and intrahepatic vessel depiction on BHSE images were similar to those obtained with the fast spin-echo techniques. The BHSE technique was superior to fat- suppressed fast spin-echo technique for showing hepatic contours (p < .01; Wilcoxon signed-rank test). CONCLUSION: The BHSE technique is quantitatively inferior to non-breath-hold fast spin-echo techniques. However, further studies with a surgical standard of reference are needed to compare the three techniques in terms of sensitivity.
This article has been cited by other articles:
![]() |
B. S. Kim, J. H. Kim, G. M. Choi, S. H. Kim, J. K. Park, B.-C. Song, and W. Kang Comparison of Three Free-Breathing T2-Weighted MRI Sequences in the Evaluation of Focal Liver Lesions Am. J. Roentgenol., January 1, 2008; 190(1): W19 - W27. [Abstract] [Full Text] [PDF] |
||||
![]() |
Y. K. Kim, C. S. Kim, G. H. Chung, S. B. Jeon, and J. M. Lee Feasibility of Application of Sensitivity Encoding to the Breath-Hold T2-Weighted Turbo Spin-Echo Sequence for Evaluation of Focal Hepatic Tumors Am. J. Roentgenol., February 1, 2005; 184(2): 497 - 504. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. Augui, O. Vignaux, C. Argaud, J. Coste, H. Gouya, and P. Legmann Liver: T2-weighted MR Imaging with Breath-hold Fast-Recovery Optimized Fast Spin-Echo Compared with Breath-hold Half-Fourier and Non-Breath-hold Respiratory-triggered Fast Spin-Echo Pulse Sequences Radiology, June 1, 2002; 223(3): 853 - 859. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Hori, T. Murakami, T. Kim, M. Kanematsu, K. Tsuda, S. Takahashi, M. Takamura, H. Hoshi, and H. Nakamura Single Breath-Hold T2-Weighted MR Imaging of the Liver: Value of Single-Shot Fast Spin-Echo and Multishot Spin-Echo Echoplanar Imaging Am. J. Roentgenol., May 1, 2000; 174(5): 1423 - 1431. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Kanematsu, H. Hoshi, K. Itoh, T. Murakami, M. Hori, H. Kondo, R. Yokoyama, and H. Nakamura Focal Hepatic Lesion Detection: Comparison of Four Fat-suppressed T2-weighted MR Imaging Pulse Sequences Radiology, May 1, 1999; 211(2): 363 - 371. [Abstract] [Full Text] |
||||