AJR ARRS Member Benefits
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Soyer, P.
Right arrow Articles by Scherrer, A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Soyer, P.
Right arrow Articles by Scherrer, A.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?

American Journal of Roentgenology, Vol 166, 593-597, Copyright © 1996 by American Roentgen Ray Society


ARTICLES

T2-weighted spin-echo MR imaging of the liver: breath-hold fast spin- echo versus non-breath-hold fast spin-echo images with and without fat suppression

P Soyer, S Le Normand, SC de Givry, C Gueye, E Somveille and A Scherrer
Department of Radiology, Hopital Foch, France.

OBJECTIVE: The goal of our study was to compare a T2-weighted breath- hold fast spin-echo (BHSE) technique with T2-weighted non-breath-hold fast spin-echo techniques for imaging the liver. SUBJECTS AND METHODS: Thirty-three patients with hepatic lesions had T2-weighted BHSE images obtained in 22 sec and conventional T2-weighted non-breath-hold fast spin-echo images obtained in 3 min 12 sec with and without fat suppression. Images were analyzed quantitatively by measuring the lesion-liver contrast, spleen-liver contrast, and signal-to-noise ratios of lesions and qualitatively by evaluating the sharpness of hepatic contours, visibility of intrahepatic vessels and other segmental landmarks, and presence of artifacts. RESULTS: Quantitatively, lesion-liver contrast, spleen-liver contrast, and signal-to-noise ratios obtained with the BHSE technique were inferior to those obtained with fast spin-echo techniques with and without fat suppression (11.2 +/- 7.1 versus 15.4 +/- 10.6 and 14.5 +/- 9.8, p < .001; 5.3 +/- 3.7 versus 8.7 +/- 3.5 and 7.0 +/- 3.8, p < .001; 16.2 +/- 8.2 versus 20.1 +/- 10.9 and 19.7 +/- 9.5, p < .01, respectively; Student's t test). Qualitatively, image artifacts and intrahepatic vessel depiction on BHSE images were similar to those obtained with the fast spin-echo techniques. The BHSE technique was superior to fat- suppressed fast spin-echo technique for showing hepatic contours (p < .01; Wilcoxon signed-rank test). CONCLUSION: The BHSE technique is quantitatively inferior to non-breath-hold fast spin-echo techniques. However, further studies with a surgical standard of reference are needed to compare the three techniques in terms of sensitivity.
Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
Am. J. Roentgenol.Home page
B. S. Kim, J. H. Kim, G. M. Choi, S. H. Kim, J. K. Park, B.-C. Song, and W. Kang
Comparison of Three Free-Breathing T2-Weighted MRI Sequences in the Evaluation of Focal Liver Lesions
Am. J. Roentgenol., January 1, 2008; 190(1): W19 - W27.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
Y. K. Kim, C. S. Kim, G. H. Chung, S. B. Jeon, and J. M. Lee
Feasibility of Application of Sensitivity Encoding to the Breath-Hold T2-Weighted Turbo Spin-Echo Sequence for Evaluation of Focal Hepatic Tumors
Am. J. Roentgenol., February 1, 2005; 184(2): 497 - 504.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
J. Augui, O. Vignaux, C. Argaud, J. Coste, H. Gouya, and P. Legmann
Liver: T2-weighted MR Imaging with Breath-hold Fast-Recovery Optimized Fast Spin-Echo Compared with Breath-hold Half-Fourier and Non-Breath-hold Respiratory-triggered Fast Spin-Echo Pulse Sequences
Radiology, June 1, 2002; 223(3): 853 - 859.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
M. Hori, T. Murakami, T. Kim, M. Kanematsu, K. Tsuda, S. Takahashi, M. Takamura, H. Hoshi, and H. Nakamura
Single Breath-Hold T2-Weighted MR Imaging of the Liver: Value of Single-Shot Fast Spin-Echo and Multishot Spin-Echo Echoplanar Imaging
Am. J. Roentgenol., May 1, 2000; 174(5): 1423 - 1431.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
M. Kanematsu, H. Hoshi, K. Itoh, T. Murakami, M. Hori, H. Kondo, R. Yokoyama, and H. Nakamura
Focal Hepatic Lesion Detection: Comparison of Four Fat-suppressed T2-weighted MR Imaging Pulse Sequences
Radiology, May 1, 1999; 211(2): 363 - 371.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1996 by the American Roentgen Ray Society.