AJR ARRS Member Benefits
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by van Heesewijk, H. P.
Right arrow Articles by Feldberg, M. A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by van Heesewijk, H. P.
Right arrow Articles by Feldberg, M. A.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?

American Journal of Roentgenology, Vol 167, 403-408, Copyright © 1996 by American Roentgen Ray Society


ARTICLES

Effects of dose reduction on digital chest imaging using a selenium detector: a study of detecting simulated diffuse interstitial pulmonary disease

HP van Heesewijk, Y van der Graaf, JC de Valois and MA Feldberg
Department of Diagnostic Radiology, St. Antonius Hospital, Nieuwegein (Utrecht), The Netherlands.

OBJECTIVE. The purpose of this study was to evaluate the effect of dose reduction on the diagnostic performance of a new digital chest imaging system in which amorphous selenium is used as the X-ray detector. Diagnostic performance was assessed for the detection of simulated diffuse interstitial pulmonary disease (DIPD). MATERIALS AND METHODS. DIPD was simulated by superimposing plastic sheets that contained small radiopaque objects (birdseed) on an anthropomorphic chest phantom. We varied the number of sheets from zero to four to simulate the degree of abnormality. We made 80 images with a standard X-ray dose, 80 images with 55% of the standard dose, and 80 images with 35% of the standard dose. Six observers were asked to indicate the presence of DIPD using a five-level scale of confidence. Two hundred forty chest images were then analyzed using receiver operating characteristic (ROC) curves. RESULTS. The area under the ROC curve was 87.2 for all readers with standard-dose imaging (95% confidence interval [CI], 83.7-90.7), 91.7 with 55% of the standard dose (95% CI, 88.8-94.6), and 90.0 with the 35% dose (95% CI, 87.1-92.9). The area under the ROC curve for subtle DIPD (one superimposed sheet) was 75.3 for all readers with standard- dose imaging (95% CI, 67.1-83.5), 79.7 with 55% of the standard dose (95% CI, 71.9-87.5), and 70.3 with the 35% dose (95% CI, 61.7-78.9). For each dose, we observed a gradual improvement of the ROC curves with each additional sheet superimposed on the chest phantom (p < .001). CONCLUSION. We found no significant difference in diagnostic performance among images made with standard X-ray dose, those made with a 55% dose, and those made with a 35% dose (95% CI).
Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
Br. J. Radiol.Home page
L J M Kroft, W J H Veldkamp, B J A Mertens, J-P A van Delft, and J Geleijns
Dose reduction in digital chest radiography and perceived image quality
Br. J. Radiol., December 1, 2007; 80(960): 984 - 988.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
L. J. M. Kroft, W. J. H. Veldkamp, B. J. A. Mertens, J. P. A. van Delft, and J. Geleijns
Detection of simulated nodules on clinical radiographs: dose reduction at digital posteroanterior chest radiography.
Radiology, November 1, 2006; 241(2): 392 - 398.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
L. J. M. Kroft, W. J. H. Veldkamp, B. J. A. Mertens, M. V. Boot, and J. Geleijns
Comparison of Eight Different Digital Chest Radiography Systems: Variation in Detection of Simulated Chest Disease
Am. J. Roentgenol., August 1, 2005; 185(2): 339 - 346.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
S. Metz, P. Damoser, R. Hollweck, R. Roggel, C. Engelke, K. Woertler, B. Renger, E. J. Rummeny, and T. M. Link
Chest Radiography with a Digital Flat-Panel Detector: Experimental Receiver Operating Characteristic Analysis
Radiology, March 1, 2005; 234(3): 776 - 784.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
U. Rapp-Bernhardt, F. W. Roehl, R. C. Gibbs, H. Schmidl, U. W. Krause, and T. M. Bernhardt
Flat-Panel X-ray Detector Based on Amorphous Silicon versus Asymmetric Screen-Film System: Phantom Study of Dose Reduction and Depiction of Simulated Findings
Radiology, May 1, 2003; 227(2): 484 - 492.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
T. M. Bernhardt, D. Otto, G. Reichel, K. Ludwig, S. Seifert, S. Kropf, and U. Rapp-Bernhardt
Detection of Simulated Interstitial Lung Disease and Catheters with Selenium, Storage Phosphor, and Film-based Radiography
Radiology, November 1, 1999; 213(2): 445 - 454.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1996 by the American Roentgen Ray Society.