American Journal of Roentgenology, Vol 167, 403-408, Copyright © 1996 by American Roentgen Ray Society
ARTICLES |
HP van Heesewijk, Y van der Graaf, JC de Valois and MA Feldberg
Department of Diagnostic Radiology, St. Antonius Hospital, Nieuwegein (Utrecht), The Netherlands.
OBJECTIVE. The purpose of this study was to evaluate the effect of dose reduction on the diagnostic performance of a new digital chest imaging system in which amorphous selenium is used as the X-ray detector. Diagnostic performance was assessed for the detection of simulated diffuse interstitial pulmonary disease (DIPD). MATERIALS AND METHODS. DIPD was simulated by superimposing plastic sheets that contained small radiopaque objects (birdseed) on an anthropomorphic chest phantom. We varied the number of sheets from zero to four to simulate the degree of abnormality. We made 80 images with a standard X-ray dose, 80 images with 55% of the standard dose, and 80 images with 35% of the standard dose. Six observers were asked to indicate the presence of DIPD using a five-level scale of confidence. Two hundred forty chest images were then analyzed using receiver operating characteristic (ROC) curves. RESULTS. The area under the ROC curve was 87.2 for all readers with standard-dose imaging (95% confidence interval [CI], 83.7-90.7), 91.7 with 55% of the standard dose (95% CI, 88.8-94.6), and 90.0 with the 35% dose (95% CI, 87.1-92.9). The area under the ROC curve for subtle DIPD (one superimposed sheet) was 75.3 for all readers with standard- dose imaging (95% CI, 67.1-83.5), 79.7 with 55% of the standard dose (95% CI, 71.9-87.5), and 70.3 with the 35% dose (95% CI, 61.7-78.9). For each dose, we observed a gradual improvement of the ROC curves with each additional sheet superimposed on the chest phantom (p < .001). CONCLUSION. We found no significant difference in diagnostic performance among images made with standard X-ray dose, those made with a 55% dose, and those made with a 35% dose (95% CI).
This article has been cited by other articles:
![]() |
L J M Kroft, W J H Veldkamp, B J A Mertens, J-P A van Delft, and J Geleijns Dose reduction in digital chest radiography and perceived image quality Br. J. Radiol., December 1, 2007; 80(960): 984 - 988. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. J. M. Kroft, W. J. H. Veldkamp, B. J. A. Mertens, J. P. A. van Delft, and J. Geleijns Detection of simulated nodules on clinical radiographs: dose reduction at digital posteroanterior chest radiography. Radiology, November 1, 2006; 241(2): 392 - 398. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. J. M. Kroft, W. J. H. Veldkamp, B. J. A. Mertens, M. V. Boot, and J. Geleijns Comparison of Eight Different Digital Chest Radiography Systems: Variation in Detection of Simulated Chest Disease Am. J. Roentgenol., August 1, 2005; 185(2): 339 - 346. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Metz, P. Damoser, R. Hollweck, R. Roggel, C. Engelke, K. Woertler, B. Renger, E. J. Rummeny, and T. M. Link Chest Radiography with a Digital Flat-Panel Detector: Experimental Receiver Operating Characteristic Analysis Radiology, March 1, 2005; 234(3): 776 - 784. [Abstract] [Full Text] [PDF] |
||||
![]() |
U. Rapp-Bernhardt, F. W. Roehl, R. C. Gibbs, H. Schmidl, U. W. Krause, and T. M. Bernhardt Flat-Panel X-ray Detector Based on Amorphous Silicon versus Asymmetric Screen-Film System: Phantom Study of Dose Reduction and Depiction of Simulated Findings Radiology, May 1, 2003; 227(2): 484 - 492. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. M. Bernhardt, D. Otto, G. Reichel, K. Ludwig, S. Seifert, S. Kropf, and U. Rapp-Bernhardt Detection of Simulated Interstitial Lung Disease and Catheters with Selenium, Storage Phosphor, and Film-based Radiography Radiology, November 1, 1999; 213(2): 445 - 454. [Abstract] [Full Text] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |