|
|
||||||||
American Journal of Roentgenology, Vol 167, 847-849, Copyright © 1996 by American Roentgen Ray Society
ARTICLES |
KJ Murphy, JA Brunberg and RH Cohan
Department of Radiology, University of Michigan Hospitals, Ann Arbor 48109-0030, USA.
OBJECTIVE: We investigated the frequency, manifestations, and severity of reactions to gadolinium contrast media in patients who underwent MR imaging at a single institution. MATERIALS AND METHODS: We reviewed the quality assurance records of 21,000 patients to whom gadolinium contrast media were administered at our institution between January 1990 and October 1994. Of these patients, 36 had adverse reactions. All 36 patients were evaluated by a radiologist at the time of the adverse reaction, and a written report of the findings was completed immediately. RESULTS: We classified adverse reactions into four groups: mild nonallergic reactions (15 patients with nausea or vomiting), mild reactions resembling allergy (12 patients with hives, diffuse erythema, or skin irritation), moderate reactions resembling allergy (seven patients with respiratory symptoms), and life-threatening reactions resembling allergy (two patients with severe chest tightness, respiratory distress, and periorbital edema). Eleven of these 36 patients who had adverse reactions also had an unusual local reaction of skin discomfort in the extremity through which gadolinium was injected. Four of the 36 patients with adverse reactions had histories of adverse reactions to iodinated contrast media. All four of these patients and one of the remaining 32 patients with adverse reactions required treatment. No patients with adverse reactions died. CONCLUSION: Although gadolinium contrast media are safe, we found that patients had adverse reactions at a frequency greater than we expected. Severe anaphylactoid reactions occurred in two patients (0.01%). This rate exceeds the rate of 0.0003% reported in the literature. The indexes of suspicion for the occurrence of reactions to gadolinium, and both the documentation and the management of adverse reactions, must be as rigorous for reactions associated with MR imaging contrast agents as they are for reactions associated with iodinated contrast media.
This article has been cited by other articles:
![]() |
M. J. Gandhi, V. R. Narra, J. J. Brown, A. Guo, D. S. Grosu, C. A. Parvin, and M. G. Scott Clinical and Economic Impact of Falsely Decreased Calcium Values Caused by Gadoversetamide Interference Am. J. Roentgenol., March 1, 2008; 190(3): W213 - W217. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. R. Dillman, J. H. Ellis, R. H. Cohan, P. J. Strouse, and S. C. Jan Allergic-Like Breakthrough Reactions to Gadolinium Contrast Agents After Corticosteroid and Antihistamine Premedication Am. J. Roentgenol., January 1, 2008; 190(1): 187 - 190. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. R. Dillman, J. H. Ellis, R. H. Cohan, P. J. Strouse, and S. C. Jan Frequency and Severity of Acute Allergic-Like Reactions to Gadolinium-Containing IV Contrast Media in Children and Adults Am. J. Roentgenol., December 1, 2007; 189(6): 1533 - 1538. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. Wessling, R. Fischbach, A. Borchert, H. Kugel, T. Allkemper, N. Osada, and W. Heindel Detection of Colorectal Polyps: Comparison of Multi-Detector Row CT and MR Colonography in a Colon Phantom Radiology, October 1, 2006; 241(1): 125 - 131. [Abstract] [Full Text] [PDF] |
||||
![]() |
A Li, C S Wong, M K Wong, C M Lee, and M C Au Yeung Acute adverse reactions to magnetic resonance contrast media - gadolinium chelates Br. J. Radiol., May 1, 2006; 79(941): 368 - 371. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. P. Kang, M. G. Scott, B. N. Joe, V. Narra, J. Heiken, and C. A. Parvin Model for Predicting the Impact of Gadolinium on Plasma Calcium Measured by the o-Cresolphthalein Method Clin. Chem., April 1, 2004; 50(4): 741 - 746. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. R. Prince, H. E. Erel, R. W. Lent, J. Blumenfeld, K. C. Kent, H. L. Bush, and Y. Wang Gadodiamide Administration Causes Spurious Hypocalcemia Radiology, June 1, 2003; 227(3): 639 - 646. [Abstract] [Full Text] [PDF] |
||||
![]() |
J F Debatin and T C Lauenstein Virtual magnetic resonance colonography Gut, June 1, 2003; 52(90004): iv17 - 22. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Kanematsu, M. Matsuo, Y. Shiratori, H. Kondo, H. Hoshi, I. Yasuda, and H. Moriwaki Thick-Section Half-Fourier Rapid Acquisition with Relaxation Enhancement MR Cholangiopancreatography: Effects of IV Administration of Gadolinium Chelate Am. J. Roentgenol., March 1, 2002; 178(3): 755 - 761. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. S. Medina, K. M. Kuntz, and S. Pomeroy Children With Headache Suspected of Having a Brain Tumor: A Cost-Effectiveness Analysis of Diagnostic Strategies Pediatrics, August 1, 2001; 108(2): 255 - 263. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. T. Cochran, K. Bomyea, and J. W. Sayre Trends in Adverse Events After IV Administration of Contrast Media Am. J. Roentgenol., June 1, 2001; 176(6): 1385 - 1388. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. Tello, B. D. Davison, M. O'Malley, H. Fenlon, K. R. Thomson, D. J. Witte, and L. Harewood MR Imaging of Renal Masses Interpreted on CT to Be Suspicious Am. J. Roentgenol., April 1, 2000; 174(4): 1017 - 1022. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. J. Seidenwurm, C. H. McDonnell III, N. Raghavan, and J. Breslau Cost Utility Analysis of Radiographic Screening for an Orbital Foreign Body before MR Imaging AJNR Am. J. Neuroradiol., February 1, 2000; 21(2): 426 - 433. [Abstract] [Full Text] |
||||
![]() |
J. S. Swan, D. G. Fryback, W. F. Lawrence, F. Sainfort, M. E. Hagenauer, and D. M. Heisey A Time-tradeoff Method for Cost--Efifectiveness Models Applied to Radiology Med Decis Making, January 1, 2000; 20(1): 79 - 88. [Abstract] [PDF] |
||||
![]() |
J. A. Kaufman, S. C. Geller, H. Bazari, and A. C. Waltman Gadolinium-based Contrast Agents as an Alternative at Vena Cavography in Patients with Renal Insufficiency—Early Experience Radiology, July 1, 1999; 212(1): 280 - 284. [Abstract] [Full Text] |
||||
![]() |
T. C. Lauenstein, S. C. Goehde, S. G. Ruehm, G. Holtmann, and J. F. Debatin MR Colonography with Barium-based Fecal Tagging: Initial Clinical Experience Radiology, April 1, 2002; 223(1): 248 - 254. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |