Image subtraction in gadolinium-enhanced MR imaging is a broadly applicable postprocessing technique that can be used with any field strength and T1-weighted sequence. This technique is typically a quick and efficient means of obtaining fat suppression that avoids the limitations of incomplete fat saturation due to field inhomogeneity and increased imaging times associated with conventional fat-suppression techniques. In particular, image subtraction may be valuable on lower strength magnetic field systems that lack effective chemical-shift fat- suppression techniques. Because source data are viewed in conjunction with subtracted images, image subtraction is unlikely to introduce errors in interpretation. By performing unenhanced and enhanced sequences in a manner amenable to image subtraction, radiologists should find this technique to be a useful and almost cost-free option.
This article has been cited by other articles:
![]() |
A. Newatia, G. Khatri, B. Friedman, and J. Hines Subtraction Imaging: Applications for Nonvascular Abdominal MRI Am. J. Roentgenol., April 1, 2007; 188(4): 1018 - 1025. [Abstract] [Full Text] [PDF] |
||||
![]() |
V. S. Lee, J. N. Morgan, A. G. S. Tan, P. V. Pandharipande, G. A. Krinsky, J. A. Barker, C. Lo, and J. C. Weinreb Celiac Artery Compression by the Median Arcuate Ligament: A Pitfall of End-expiratory MR Imaging Radiology, August 1, 2003; 228(2): 437 - 442. [Abstract] [Full Text] [PDF] |
||||