|
|
||||||||
American Journal of Roentgenology, Vol 168, 467-472, Copyright © 1997 by American Roentgen Ray Society
ARTICLES |
RY Kanterman, MD Darcy, WD Middleton, KM Sterling, SA Teefey and TK Pilgram
Mallinckrodt Institute of Radiology, Washington University School of Medicine, St. Louis, MO 63112, USA.
OBJECTIVE: Our purpose was to determine the overall accuracy of Doppler sonography and the accuracy of specific Doppler parameters associated with a compromised transjugular intrahepatic portosystemic shunt (TIPS). MATERIALS AND METHODS: For 43 patients who had undergone TIPS, 64 correlated sonogram-venogram paired examinations were analyzed. Sonographic parameters assessed included absolute velocities plus absolute and percentage changes in velocities measured in the main portal vein (MPV) and in several intrashunt locations (including peak and minimum velocity). Direction of flow and change in direction of flow in the left and right portal veins were also examined. TIPS malfunction was defined as any shunt with greater than or equal to 50% stenosis or any stenosis with a portosystemic gradient greater than 15 mm Hg. RESULTS: The prospective interpretation of the sonograms using all available parameters resulted in a sensitivity of 92% and a specificity of 72% for detecting TIPS malfunction. Peak shunt velocity (absolute velocity and velocity change), distal shunt velocity, MPV velocity (absolute velocity and percentage change in velocity), change in minimum shunt velocity, and direction of flow in branch portal veins were found to have statistically significant differences between normal and abnormal shunts. Sensitivities for these individual parameters ranged from 64% to 84%, and specificities ranged from 70% to 100%. When either the MPV velocity or the distal shunt velocity was abnormal, the sensitivity was 94%. When both parameters were abnormal, the specificity for detecting TIPS malfunction was 100%. CONCLUSION: Doppler sonography is a sensitive and relatively specific means of revealing TIPS malfunction. Accuracy depends on analysis of multiple sonographic parameters.
This article has been cited by other articles:
![]() |
D. Lake, M. Guimaraes, S. Ackerman, C. Hannegan, C. Schonholz, J. B. Selby, and R. Uflacker Comparative Results of Doppler Sonography After TIPS Using Covered and Bare Stents. Am. J. Roentgenol., April 1, 2006; 186(4): 1138 - 1143. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. T. Lau, M. Scott, S. W. Stavropoulos, M. C. Soulen, J. A. Solomon, and T. W. I. Clark Dacron-covered Stent-Grafts in Transjugular Intrahepatic Portosystemic Shunts: Initial Experience Radiology, August 1, 2005; 236(2): 725 - 729. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. G. Sheiman, T. Vrachliotis, D. P. Brophy, and B. J. Ransil Transmitted Cardiac Pulsations as an Indicator of Transjugular Intrahepatic Portosystemic Shunt Function: Initial Observations Radiology, July 1, 2002; 224(1): 225 - 230. [Abstract] [Full Text] |
||||
![]() |
R. H. Wachsberg, P. Bahramipour, C. T. Sofocleous, and A. Barone Hepatofugal Flow in the Portal Venous System: Pathophysiology, Imaging Findings, and Diagnostic Pitfalls RadioGraphics, January 1, 2002; 22(1): 123 - 140. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. Zizka, P. Elias, A. Krajina, A. Michl, M. Lojik, P. Ryska, J. Maskova, P. Hulek, V. Safka, T. Vanasek, et al. Value of Doppler Sonography in Revealing Transjugular Intrahepatic Portosystemic Shunt Malfunction: A 5-Year Experience in 216 Patients Am. J. Roentgenol., July 1, 2000; 175(1): 141 - 148. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. A. Kliewer, B. S. Hertzberg, J. P. Heneghan, P. V. Suhocki, D. H. Sheafor, P. A. Gannon Jr., and E. K. Paulson Transjugular Intrahepatic Portosystemic Shunts (TIPS): Effects of Respiratory State and Patient Position on the Measurement of Doppler Velocities Am. J. Roentgenol., July 1, 2000; 175(1): 149 - 152. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. S. Johnson Transjugular Intrahepatic Portosystemic Shunt: Accuracy of Helical CT Angiography in the Detection of Abnormalities Radiology, April 1, 2000; 215(1): 25 - 26. [Full Text] |
||||
![]() |
S. Chopra, G. D. Dodd III, K. N. Chintapalli, H. Rhim, C. E. Encarnacion, J. C. Palmaz, C. C. Esola, and A. A. Ghiatas Transjugular Intrahepatic Portosystemic Shunt: Accuracy of Helical CT Angiography in the Detection of Shunt Abnormalities Radiology, April 1, 2000; 215(1): 115 - 122. [Abstract] [Full Text] |
||||
![]() |
Z. J. Haskal Improved Patency of Transjugular Intrahepatic Portosystemic Shunts in Humans: Creation and Revision with PTFE Stent-Grafts Radiology, December 1, 1999; 213(3): 759 - 766. [Abstract] [Full Text] |
||||
![]() |
M. Cejna, M. Peck-Radosavljevic, S. A. Thurnher, K. Hittmair, M. Schoder, and J. Lammer Creation of Transjugular Intrahepatic Portosystemic Shunts with Stent-Grafts: Initial Experiences with a Polytetrafluoroethylene-covered Nitinol Endoprosthesis Radiology, November 1, 2001; 221(2): 437 - 446. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |